Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 2.540 kW
07/04/2026 22:48 (2229 days) Production Consumption NET Usage
Now 0.225 kW 2.765 kW 2.540 kW
Today 33.151 kWh (1.452 kW) 42.274 kWh (1.851 kW) 9.123 kWh (0.399 kW)
  - This Week 209.103 kWh (30.084 kWh/day) 244.191 kWh (35.132 kWh/day) 35.088 kWh (5.048 kWh/day)
  - This Month 127.502 kWh (32.269 kWh/day) 170.051 kWh (43.037 kWh/day) 42.549 kWh (10.768 kWh/day)
  - This Year 3.737 MWh (20.207 kWh/day) 3.457 MWh (18.691 kWh/day) -0.281 MWh (-1.517 kWh/day)
Yesterday 33.078 kWh (1.378 kW) 41.779 kWh (1.741 kW) 8.701 kWh (0.363 kW)
Last 7 Days 209.103 kWh (29.872 kWh/day) 244.976 kWh (34.997 kWh/day) 35.873 kWh (5.125 kWh/day)
Last 30 Days (06/04/2026) 850.535 kWh (28.351 kWh/day) 829.113 kWh (27.637 kWh/day) -21.422 kWh (-0.714 kWh/day)
Last One Year 6.723 MWh (18.420 kWh/day) 7.747 MWh (21.226 kWh/day) 1.024 MWh (2.805 kWh/day)
Lifetime Since PTO 39.303 MWh (17.625 kW/day) 42.968 MWh (19.268 kW/day) 3.665 MWh (1.643 kW/day)
Lifetime Since Install 39.337 MWh 43.548 MWh 4.211 MWh
Voltage/Current 249.4 V / 0.9 A 249.3 V / 11.1 A 249.4 V / 10.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/20/2020 23:26 (14.6 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 26.490 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.299 1.822 1.963 14.563 0.000 kW
1.758 kWh
0.000 kW
10.549 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.769 1.898 14.078
03 - 202224****** IQ7+M [0] ---- 0.000 0.297 1.766 1.891 14.011
04 - 202232****** IQ7+ [0] ---- 0.000 0.298 1.775 1.900 14.131
05 - 202244****** IQ7+M [0] ---- 0.000 0.299 1.624 1.750 12.855
06 - 202245****** IQ7+M [0] ---- 0.000 0.297 1.792 1.915 14.273
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.296 1.660 1.758 12.712 0.000 kW
1.666 kWh
0.000 kW
8.328 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.300 1.661 1.799 13.117
09 - 202217****** IQ7+ [0] ---- 0.000 0.302 1.669 1.798 12.896
10 - 202244****** IQ7+M [0] ---- 0.000 0.299 1.673 1.810 13.190
11 - 202224****** IQ7+M [0] ---- 0.000 0.297 1.665 1.802 13.202
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.296 1.910 1.983 15.005 0.000 kW
1.903 kWh
0.000 kW
7.613 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.297 1.887 1.940 14.650
14 - 202216****** IQ7+ [0] ---- 0.000 0.296 1.924 1.994 15.055
15 - 202245****** IQ7+M [0] ---- 0.000 0.294 1.893 1.965 14.795
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 56.02 V Current/Power 174.92 A (9.798 kW)
Remain Capacity/Energy 518.7 Ah (26.6 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 89.9 % State Of Health 96.2 %
Run Time 20m to full Report Date 2020-06-20 23:52
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.