Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 4.977 kW
03/09/2026 18:56 (2112 days) Production Consumption NET Usage
Now 0.000 kW 4.977 kW 4.977 kW
Today 25.455 kWh (1.343 kW) 10.364 kWh (0.547 kW) -15.091 kWh (-0.796 kW)
  - This Week 36.181 kWh (20.217 kWh/day) 22.834 kWh (12.759 kWh/day) -13.347 kWh (-7.458 kWh/day)
  - This Month 129.889 kWh (14.778 kWh/day) 129.133 kWh (14.692 kWh/day) -0.756 kWh (-0.086 kWh/day)
  - This Year 0.764 MWh (11.267 kWh/day) 1.229 MWh (18.129 kWh/day) 0.465 MWh (6.862 kWh/day)
Yesterday 10.726 kWh (0.447 kW) 12.470 kWh (0.520 kW) 1.744 kWh (0.073 kW)
Last 7 Days 81.632 kWh (11.662 kWh/day) 105.838 kWh (15.120 kWh/day) 24.206 kWh (3.458 kWh/day)
Last 30 Days 383.013 kWh (12.767 kWh/day) 497.318 kWh (16.577 kWh/day) 114.305 kWh (3.810 kWh/day)
Last One Year 6.041 MWh (16.551 kWh/day) 7.789 MWh (21.339 kWh/day) 1.748 MWh (4.788 kWh/day)
Lifetime Since PTO 36.329 MWh (17.195 kW/day) 40.740 MWh (19.282 kW/day) 4.410 MWh (2.087 kW/day)
Lifetime Since Install 36.363 MWh 41.320 MWh 4.956 MWh
Voltage/Current 248.8 V / 0.0 A 248.7 V / 20.0 A 248.8 V / 20.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/29/2025 23:25 (14.5 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 27.935 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VC-- 0.000 0.282 2.005 1.910 10.909 0.000 kW
1.900 kWh
0.000 kW
11.400 kWh
02 - 202244****** IQ7+M [5] VC-- 0.000 0.269 1.867 1.783 10.289
03 - 202224****** IQ7+M [5] VC-- 0.000 0.279 1.913 1.832 10.535
04 - 202232****** IQ7+ [5] VC-- 0.000 0.282 1.961 1.875 10.737
05 - 202244****** IQ7+M [5] VCOP 0.000 0.270 1.729 1.639 9.500
06 - 202245****** IQ7+M [5] VC-- 0.000 0.276 1.925 1.838 10.586
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.271 1.827 1.771 10.035 0.000 kW
1.828 kWh
0.000 kW
9.138 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.274 1.797 1.701 9.809
09 - 202217****** IQ7+ [5] VCOP 0.000 0.271 1.808 1.722 9.933
10 - 202244****** IQ7+M [5] VCOP 0.000 0.270 1.838 1.756 10.047
11 - 202224****** IQ7+M [5] VCOP 0.000 0.277 1.868 1.783 10.085
back 12 - 202211****** IQ7+ [5] VC-- 0.000 0.232 1.809 1.808 10.477 0.000 kW
1.849 kWh
0.000 kW
7.397 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.238 1.819 1.784 10.532
14 - 202216****** IQ7+ [5] VCOP 0.000 0.238 1.882 1.877 11.019
15 - 202245****** IQ7+M [5] VCOP 0.000 0.239 1.887 1.884 11.116
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Charger History
Voltage PV 0.23 V Voltage Charge 52.37 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 32.8 °C / 29.8 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-07-29 23:59
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.66 V Current/Power -6.40 A (-0.337 kW)
Remain Capacity/Energy 344.7 Ah (17.7 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 58.1 % State Of Health 98.9 %
Run Time 2d 5h 51m to empty Report Date 2025-07-29 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.