Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.313 kW
11/04/2025 14:11 (1987 days) Production Consumption NET Usage
Now 2.583 kW 0.270 kW -2.313 kW
Today 15.807 kWh (1.112 kW) 5.379 kWh (0.378 kW) -10.428 kWh (-0.734 kW)
  - This Week 39.624 kWh (15.288 kWh/day) 45.808 kWh (17.674 kWh/day) 6.184 kWh (2.386 kWh/day)
  - This Month 56.562 kWh (15.745 kWh/day) 61.996 kWh (17.258 kWh/day) 5.434 kWh (1.513 kWh/day)
  - This Year 5.634 MWh (18.318 kWh/day) 6.394 MWh (20.789 kWh/day) 0.760 MWh (2.470 kWh/day)
Yesterday 6.646 kWh (0.277 kW) 14.112 kWh (0.588 kW) 7.466 kWh (0.311 kW)
Last 7 Days 74.080 kWh (10.584 kWh/day) 110.927 kWh (15.848 kWh/day) 36.847 kWh (5.264 kWh/day)
Last 30 Days 425.690 kWh (14.190 kWh/day) 478.568 kWh (15.953 kWh/day) 52.878 kWh (1.763 kWh/day)
Last One Year 6.195 MWh (16.972 kWh/day) 7.436 MWh (20.373 kWh/day) 1.241 MWh (3.401 kWh/day)
Lifetime Since PTO 35.085 MWh (17.652 kW/day) 38.347 MWh (19.293 kW/day) 3.262 MWh (1.641 kW/day)
Lifetime Since Install 35.119 MWh 38.927 MWh 3.808 MWh
Voltage/Current 249.5 V / 10.4 A 249.4 V / 1.1 A 249.5 V / -9.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/10/2025 23:59 (11.5 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 19.166 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.256 0.912 1.702 9.689 0.000 kW
0.902 kWh
0.000 kW
5.413 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.242 0.692 1.621 9.223
03 - 202224****** IQ7+M [5] VCOP 0.000 0.246 0.651 1.635 9.493
04 - 202232****** IQ7+ [5] VCOP 0.000 0.257 0.938 1.677 9.547
05 - 202244****** IQ7+M [5] VCOP 0.000 0.259 1.353 1.614 9.106
06 - 202245****** IQ7+M [5] VCOP 0.000 0.249 0.868 1.646 9.302
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.837 1.727 9.659 0.000 kW
1.756 kWh
0.000 kW
8.780 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.967 1.853 10.148
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.983 1.813 10.154
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 0.969 1.847 10.308
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 2.025 1.863 10.349
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.187 1.188 1.076 6.333 0.000 kW
1.243 kWh
0.000 kW
4.973 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.191 1.237 1.122 6.650
14 - 202216****** IQ7+ [5] VCOP 0.000 0.193 1.278 1.164 6.883
15 - 202245****** IQ7+M [5] VCOP 0.000 0.192 1.270 1.159 6.844
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Charger History
Voltage PV 1.05 V Voltage Charge 52.88 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 27.6 °C / 24.5 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-03-10 23:57
voltage in/out power and energy internal/external temperature

Battery History
Voltage 53.12 V Current/Power -6.26 A (-0.333 kW)
Remain Capacity/Energy 499.1 Ah (25.6 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 84.1 % State Of Health 98.9 %
Run Time 3d 7h 43m to empty Report Date 2025-03-10 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.