Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.391 kW
03/09/2026 22:04 (2112 days) Production Consumption NET Usage
Now 0.000 kW 0.391 kW 0.391 kW
Today 25.455 kWh (1.152 kW) 14.357 kWh (0.650 kW) -11.098 kWh (-0.502 kW)
  - This Week 36.181 kWh (18.841 kWh/day) 26.827 kWh (13.970 kWh/day) -9.354 kWh (-4.871 kWh/day)
  - This Month 129.889 kWh (14.561 kWh/day) 133.126 kWh (14.924 kWh/day) 3.237 kWh (0.363 kWh/day)
  - This Year 0.764 MWh (11.246 kWh/day) 1.233 MWh (18.153 kWh/day) 0.469 MWh (6.907 kWh/day)
Yesterday 10.726 kWh (0.447 kW) 12.470 kWh (0.520 kW) 1.744 kWh (0.073 kW)
Last 7 Days 80.638 kWh (11.520 kWh/day) 106.673 kWh (15.239 kWh/day) 26.035 kWh (3.719 kWh/day)
Last 30 Days 382.021 kWh (12.734 kWh/day) 494.901 kWh (16.497 kWh/day) 112.880 kWh (3.763 kWh/day)
Last One Year 6.041 MWh (16.551 kWh/day) 7.788 MWh (21.336 kWh/day) 1.747 MWh (4.786 kWh/day)
Lifetime Since PTO 36.329 MWh (17.194 kW/day) 40.744 MWh (19.283 kW/day) 4.414 MWh (2.089 kW/day)
Lifetime Since Install 36.363 MWh 41.324 MWh 4.960 MWh
Voltage/Current 250.9 V / 0.0 A 250.9 V / 1.6 A 250.9 V / 1.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/05/2025 23:35 (14.7 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 27.773 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.279 1.956 2.228 11.557 0.000 kW
1.874 kWh
0.000 kW
11.241 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.264 1.837 2.114 10.929
03 - 202224****** IQ7+M [0] ---- 0.000 0.276 1.880 1.796 10.823
04 - 202232****** IQ7+ [0] ---- 0.000 0.279 1.922 2.226 11.353
05 - 202244****** IQ7+M [0] ---- 0.000 0.265 1.751 2.035 10.430
06 - 202245****** IQ7+M [0] ---- 0.000 0.271 1.895 2.173 11.211
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.270 1.812 2.082 10.627 0.000 kW
1.812 kWh
0.000 kW
9.058 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.272 1.781 1.999 10.429
09 - 202217****** IQ7+ [0] ---- 0.000 0.270 1.804 2.024 10.542
10 - 202244****** IQ7+M [0] ---- 0.000 0.267 1.820 2.098 10.701
11 - 202224****** IQ7+M [0] ---- 0.000 0.273 1.840 2.147 10.830
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.245 1.813 1.967 10.894 0.000 kW
1.868 kWh
0.000 kW
7.474 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.250 1.843 1.956 11.031
14 - 202216****** IQ7+ [0] ---- 0.000 0.254 1.903 2.045 11.444
15 - 202245****** IQ7+M [0] ---- 0.000 0.257 1.914 2.070 11.478
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Charger History
Voltage PV 1.01 V Voltage Charge 52.87 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 29.5 °C / 26.3 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-06-05 23:56
voltage in/out power and energy internal/external temperature

Battery History
Voltage 53.13 V Current/Power -6.25 A (-0.332 kW)
Remain Capacity/Energy 506.3 Ah (25.9 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 85.4 % State Of Health 98.9 %
Run Time 3d 9h 0m to empty Report Date 2025-06-05 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack