Importing from grid by 0.370 kW
09/07/2025 05:50 (1929 days) Production Consumption NET Usage
Now 0.000 kW 0.370 kW 0.370 kW
Today 0.000 kWh (0.000 kW) 2.416 kWh (0.413 kW) 2.416 kWh (0.413 kW)
  - This Week 0.000 kWh (0.000 kWh/day) 2.416 kWh (9.913 kWh/day) 2.416 kWh (9.913 kWh/day)
  - This Month 136.928 kWh (21.931 kWh/day) 198.141 kWh (31.736 kWh/day) 61.213 kWh (9.804 kWh/day)
  - This Year 4.644 MWh (18.633 kWh/day) 5.369 MWh (21.541 kWh/day) 0.725 MWh (2.907 kWh/day)
Yesterday 15.347 kWh (0.639 kW) 67.410 kWh (2.807 kW) 52.063 kWh (2.168 kW)
Last 7 Days 165.253 kWh (23.605 kWh/day) 211.899 kWh (30.269 kWh/day) 46.646 kWh (6.663 kWh/day)
Last 30 Days 726.759 kWh (24.225 kWh/day) 833.881 kWh (27.796 kWh/day) 107.122 kWh (3.571 kWh/day)
Last One Year 6.306 MWh (17.278 kWh/day) 7.070 MWh (19.370 kWh/day) 0.764 MWh (2.093 kWh/day)
Lifetime Since PTO 34.095 MWh (17.673 kW/day) 37.321 MWh (19.345 kW/day) 3.226 MWh (1.672 kW/day)
Lifetime Since Install 34.129 MWh 37.901 MWh 3.772 MWh
Voltage/Current 253.1 V / 0.0 A 253.1 V / 1.5 A 253.1 V / 1.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:1, pcu_level:5]
Recent Report Data/Time 08/10/2025 23:58 (23.9 hours) Number of Devices 16 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 34.246 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.269 2.026 2.141 12.745 0.000 kW
1.946 kWh
0.000 kW
11.676 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.256 1.900 2.003 11.973
03 - 202224****** IQ7+M [0] ---- 0.000 0.267 1.981 2.086 12.438
04 - 202232****** IQ7+ [0] ---- 0.000 0.273 2.039 2.149 12.709
05 - 202244****** IQ7+M [0] ---- 0.000 0.258 1.799 1.888 11.360
06 - 202245****** IQ7+M [0] ---- 0.000 0.263 1.931 2.040 12.245
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.270 1.913 2.024 11.839 0.000 kW
1.925 kWh
0.000 kW
9.626 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.273 1.900 1.993 11.760
09 - 202217****** IQ7+ [0] ---- 0.000 0.271 1.903 1.989 11.770
10 - 202244****** IQ7+M [0] ---- 0.000 0.270 1.937 2.035 11.945
11 - 202224****** IQ7+M [0] ---- 0.000 0.275 1.973 2.087 12.170
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.224 1.820 1.920 11.519 0.000 kW
1.859 kWh
0.000 kW
7.436 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.229 1.828 1.904 11.594
14 - 202216****** IQ7+ [0] ---- 0.000 0.230 1.889 1.992 12.048
15 - 202245****** IQ7+M [0] ---- 0.000 0.232 1.899 2.001 12.099
wind 16 - 122214****** IQ7PD [5] VCOP 0.230 0.231 5.507 5.487 38.458 0.230 kW
5.507 kWh
0.230 kW
5.507 kWh
Panel Layout Each Group Production

Charger History
Voltage PV 1.05 V Voltage Charge 52.85 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 32.0 °C / 29.2 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-08-10 23:59
voltage in/out power and energy internal/external temperature

Battery History
Voltage 53.13 V Current/Power -6.33 A (-0.336 kW)
Remain Capacity/Energy 502.8 Ah (25.7 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 84.8 % State Of Health 98.9 %
Run Time 3d 7h 26m to empty Report Date 2025-08-10 23:56