Date Offset  [+30][+10][+05][+01][-01][-05][-10]

Exporting to grid by 1.052 kW
07/01/2026 08:56 (2226 days) Production Consumption NET Usage
Now 1.391 kW 0.339 kW -1.052 kW
Today 1.719 kWh (0.192 kW) 7.100 kWh (0.792 kW) 5.381 kWh (0.600 kW)
  - This Week 83.320 kWh (24.702 kWh/day) 81.240 kWh (24.085 kWh/day) -2.080 kWh (-0.617 kWh/day)
  - This Month 1.719 kWh (4.601 kWh/day) 7.100 kWh (19.005 kWh/day) 5.381 kWh (14.404 kWh/day)
  - This Year 3.612 MWh (19.912 kWh/day) 3.294 MWh (18.161 kWh/day) -0.318 MWh (-1.751 kWh/day)
Yesterday 26.873 kWh (1.121 kW) 21.329 kWh (0.889 kW) -5.544 kWh (-0.231 kW)
Last 7 Days 170.875 kWh (24.411 kWh/day) 156.280 kWh (22.326 kWh/day) -14.595 kWh (-2.085 kWh/day)
Last 30 Days (06/01/2026) 874.781 kWh (29.159 kWh/day) 719.915 kWh (23.997 kWh/day) -154.866 kWh (-5.162 kWh/day)
Last One Year 6.696 MWh (18.344 kWh/day) 7.718 MWh (21.145 kWh/day) 1.023 MWh (2.802 kWh/day)
Lifetime Since PTO 39.177 MWh (17.597 kW/day) 42.805 MWh (19.226 kW/day) 3.627 MWh (1.629 kW/day)
Lifetime Since Install 39.211 MWh 43.385 MWh 4.173 MWh
Voltage/Current 248.4 V / 5.6 A 248.4 V / 1.4 A 248.4 V / -4.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 06/02/2026 23:56 (23.9 hours) Number of Devices 18 set
Current Power 0.320 kW (0.018 kW/panel) Today Energy 38.045 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 2.094 2.158 13.557 0.000 kW
1.962 kWh
0.000 kW
11.770 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.950 2.030 12.739
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.965 2.049 13.024
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 2.011 2.091 13.146
05 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.737 1.824 11.839
06 - 202245****** IQ7+M [5] VCOP 0.000 0.296 2.013 2.097 13.126
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.291 1.826 1.910 12.206 0.000 kW
1.844 kWh
0.000 kW
9.219 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.819 1.954 12.090
09 - 202217****** IQ7+ [5] VCOP 0.000 0.294 1.838 1.937 12.212
10 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.850 1.931 12.391
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.886 1.953 12.564
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.278 2.176 2.192 13.173 0.000 kW
2.209 kWh
0.000 kW
8.837 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.286 2.190 2.188 13.127
14 - 202216****** IQ7+ [5] VCOP 0.000 0.278 2.236 2.258 13.575
15 - 202245****** IQ7+M [5] VCOP 0.000 0.292 2.236 2.270 13.586
wind 16 - 202320****** IQ7XS [0] ---- 0.320 0.322 7.207 5.083 37.547 0.107 kW
2.740 kWh
0.320 kW
8.219 kWh
17 - 122344****** IQ7AS [4] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [0] ---- 0.000 0.154 1.012 0.858 4.926
Panel Layout Each Group Production

Charger History
Voltage PV 0.47 V Voltage Charge 52.36 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 29.0 °C / 25.6 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2026-06-02 23:58
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.62 V Current/Power -7.84 A (-0.413 kW)
Remain Capacity/Energy 313.6 Ah (16.1 kWh) Full Capacity/Energy 548.1 Ah (28.1 kWh)
State Of Charge 57.2 % State Of Health 91.4 %
Run Time 1d 16h 0m to empty Report Date 2026-06-02 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.