Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.142 kW
09/04/2025 07:21 (1926 days) Production Consumption NET Usage
Now 0.284 kW 0.142 kW -0.142 kW
Today 0.092 kWh (0.012 kW) 2.891 kWh (0.393 kW) 2.799 kWh (0.380 kW)
  - This Week 104.469 kWh (24.253 kWh/day) 106.990 kWh (24.838 kWh/day) 2.521 kWh (0.585 kWh/day)
  - This Month 76.144 kWh (23.028 kWh/day) 90.816 kWh (27.465 kWh/day) 14.672 kWh (4.437 kWh/day)
  - This Year 4.583 MWh (18.609 kWh/day) 5.262 MWh (21.362 kWh/day) 0.678 MWh (2.753 kWh/day)
Yesterday 27.115 kWh (1.129 kW) 21.101 kWh (0.878 kW) -6.014 kWh (-0.250 kW)
Last 7 Days 177.232 kWh (25.319 kWh/day) 156.050 kWh (22.293 kWh/day) -21.182 kWh (-3.026 kWh/day)
Last 30 Days 726.444 kWh (24.214 kWh/day) 795.791 kWh (26.526 kWh/day) 69.347 kWh (2.312 kWh/day)
Last One Year 6.330 MWh (17.341 kWh/day) 6.997 MWh (19.170 kWh/day) 0.668 MWh (1.829 kWh/day)
Lifetime Since PTO 34.034 MWh (17.668 kW/day) 37.214 MWh (19.319 kW/day) 3.179 MWh (1.650 kW/day)
Lifetime Since Install 34.068 MWh 37.794 MWh 3.725 MWh
Voltage/Current 249.8 V / 1.1 A 249.8 V / 0.6 A 249.8 V / -0.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:1, pcu_level:5]
Recent Report Data/Time 08/05/2025 23:55 (23.8 hours) Number of Devices 16 set
Current Power 0.229 kW (0.014 kW/panel) Today Energy 28.094 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.259 1.590 2.017 11.790 0.000 kW
1.541 kWh
0.000 kW
9.246 kWh
02 - 202244****** IQ7+M [5] VC-- 0.000 0.247 1.504 1.890 11.057
03 - 202224****** IQ7+M [5] VCOP 0.000 0.261 1.561 1.959 11.429
04 - 202232****** IQ7+ [5] VCOP 0.000 0.266 1.588 1.995 11.669
05 - 202244****** IQ7+M [5] VCOP 0.000 0.251 1.465 1.788 10.396
06 - 202245****** IQ7+M [5] VCOP 0.000 0.257 1.538 1.938 11.361
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.244 1.461 1.868 10.786 0.000 kW
1.481 kWh
0.000 kW
7.406 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.250 1.485 1.860 10.667
09 - 202217****** IQ7+ [5] VCOP 0.000 0.252 1.483 1.864 10.716
10 - 202244****** IQ7+M [5] VCOP 0.000 0.247 1.481 1.882 10.853
11 - 202224****** IQ7+M [5] VCOP 0.000 0.251 1.496 1.918 11.005
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.235 1.434 1.807 11.029 0.000 kW
1.489 kWh
0.000 kW
5.954 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.242 1.481 1.829 11.158
14 - 202216****** IQ7+ [5] VCOP 0.000 0.244 1.515 1.875 11.548
15 - 202245****** IQ7+M [5] VCOP 0.000 0.245 1.523 1.880 11.605
wind 16 - 122214****** IQ7PD [5] VCOP 0.229 0.230 5.488 5.502 19.845 0.229 kW
5.488 kWh
0.229 kW
5.488 kWh
Panel Layout Each Group Production

Charger History
Voltage PV 1.06 V Voltage Charge 52.77 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 32.0 °C / 29.3 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-08-05 23:59
voltage in/out power and energy internal/external temperature

Battery History
Voltage 53.06 V Current/Power -6.23 A (-0.331 kW)
Remain Capacity/Energy 401.7 Ah (20.6 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 67.7 % State Of Health 98.9 %
Run Time 2d 16h 28m to empty Report Date 2025-08-05 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.