| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Importing from grid by 0.940 kW | |||
|---|---|---|---|
| 07/01/2026 22:40 (2226 days) | Production | Consumption | NET Usage |
| Now | 0.000 kW | 0.940 kW | 0.940 kW |
| Today | 25.631 kWh (1.129 kW) | 39.995 kWh (1.762 kW) | 14.364 kWh (0.633 kW) |
| - This Week | 107.232 kWh (27.181 kWh/day) | 114.135 kWh (28.931 kWh/day) | 6.903 kWh (1.750 kWh/day) |
| - This Month | 25.631 kWh (27.103 kWh/day) | 39.995 kWh (42.291 kWh/day) | 14.364 kWh (15.189 kWh/day) |
| - This Year | 3.635 MWh (19.981 kWh/day) | 3.327 MWh (18.284 kWh/day) | -0.309 MWh (-1.697 kWh/day) |
| Yesterday | 26.873 kWh (1.121 kW) | 21.329 kWh (0.889 kW) | -5.544 kWh (-0.231 kW) |
| Last 7 Days | 164.808 kWh (23.544 kWh/day) | 170.692 kWh (24.385 kWh/day) | 5.884 kWh (0.841 kWh/day) |
| Last 30 Days (06/01/2026) | 865.447 kWh (28.848 kWh/day) | 747.340 kWh (24.911 kWh/day) | -118.107 kWh (-3.937 kWh/day) |
| Last One Year | 6.700 MWh (18.355 kWh/day) | 7.728 MWh (21.172 kWh/day) | 1.028 MWh (2.817 kWh/day) |
| Lifetime Since PTO | 39.201 MWh (17.603 kW/day) | 42.838 MWh (19.236 kW/day) | 3.636 MWh (1.633 kW/day) |
| Lifetime Since Install | 39.235 MWh | 43.418 MWh | 4.182 MWh |
| Voltage/Current | 249.9 V / 0.0 A | 249.9 V / 3.8 A | 249.9 V / 3.8 A |
|
|||
| Micro-inverters [pcu_num:5, pcu_level:1] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 08/23/2025 23:58 (23.9 hours) | Number of Devices | 18 set | |||||||
| Current Power | 0.230 kW (0.013 kW/panel) | Today Energy | 35.064 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.281 | 2.078 | 2.099 | 10.364 | 0.000 kW 2.021 kWh |
0.000 kW 12.126 kWh |
| 02 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.269 | 1.977 | 1.985 | 9.848 | |||
| 03 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.279 | 2.067 | 2.074 | 10.257 | |||
| 04 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.284 | 2.128 | 2.127 | 10.445 | |||
| 05 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.271 | 1.892 | 1.889 | 9.540 | |||
| 06 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.276 | 1.983 | 1.992 | 9.967 | |||
| front | 07 - 202206****** | IQ7+ | [0] ---- | 0.000 | 0.290 | 2.024 | 2.009 | 9.852 | 0.000 kW 2.053 kWh |
0.000 kW 10.264 kWh |
| 08 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.293 | 2.039 | 2.016 | 9.952 | |||
| 09 - 202217****** | IQ7+ | [0] ---- | 0.000 | 0.291 | 2.023 | 1.987 | 9.907 | |||
| 10 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.289 | 2.065 | 2.042 | 10.069 | |||
| 11 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.295 | 2.113 | 2.106 | 10.279 | |||
| back | 12 - 202211****** | IQ7+ | [0] ---- | 0.000 | 0.227 | 1.755 | 1.797 | 8.824 | 0.000 kW 1.792 kWh |
0.000 kW 7.168 kWh |
| 13 - 202223****** | IQ7+ | [0] ---- | 0.000 | 0.232 | 1.760 | 1.793 | 8.910 | |||
| 14 - 202216****** | IQ7+ | [0] ---- | 0.000 | 0.234 | 1.824 | 1.860 | 9.249 | |||
| 15 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.235 | 1.828 | 1.863 | 9.285 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.077 kW 1.836 kWh |
0.230 kW 5.507 kWh |
| 17 - 122344****** | IQ7AS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
| 18 - 122214****** | IQ7PD | [0] ---- | 0.230 | 0.231 | 5.507 | 5.507 | 38.429 | |||
|
||||||||||
| Charger History | |||||
|---|---|---|---|---|---|
| Voltage PV | 0.67 V | Voltage Charge | 52.84 V | Current/Power | 0.00 A / 0.000 kW |
| Int/Ext Temp | 31.5 °C / 29.0 °C | Flags | 00/00/00 | Energy Today | 0.000 kWh @ 2025-08-23 23:57 |
|
|||||
| Battery History | |||
|---|---|---|---|
| Voltage | 53.13 V | Current/Power | -6.37 A (-0.338 kW) |
| Remain Capacity/Energy | 432.8 Ah (22.2 kWh) | Full Capacity/Energy | 593.1 Ah (30.4 kWh) |
| State Of Charge | 73.0 % | State Of Health | 98.9 % |
| Run Time | 2d 19h 56m to empty | Report Date | 2025-08-23 23:55 |
|
|||
| Voltage | 53.12 V | Cell (MIN/MAX) | 3.314 V / 3.324 V (0.010 V) |
|---|---|---|---|
| Current/Power | -1.94 A (-103 W) | Runtime | 3d 2h 14m to empty |
| Remain Capacity/Energy | 144.3 Ah (7.4 kWh) | Full Capacity/Energy | 197.7 Ah (10.1 kWh) |
| State Of Charge | 73.0 % | State Of Health | 98.8 % |
| Temperature | 25.5 °C | Cycle | 213 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-08-23 23:55 |
| Voltage | 53.13 V | Cell (MIN/MAX) | 3.320 V / 3.321 V (0.001 V) |
|---|---|---|---|
| Current/Power | -1.05 A (-55 W) | Runtime | 3d 16h 33m to empty |
| Remain Capacity/Energy | 93.0 Ah (4.8 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 93.5 % | State Of Health | 99.5 % |
| Temperature | 26.0 °C | Cycle | 148 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-08-23 23:55 |
| Voltage | 53.17 V | Cell (MIN/MAX) | 3.321 V / 3.323 V (0.002 V) |
|---|---|---|---|
| Current/Power | -1.09 A (-58 W) | Runtime | 3d 12h 44m to empty |
| Remain Capacity/Energy | 92.6 Ah (4.7 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 93.1 % | State Of Health | 99.5 % |
| Temperature | 25.3 °C | Cycle | 152 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-08-23 23:56 |
| Voltage | 53.11 V | Cell (MIN/MAX) | 3.318 V / 3.320 V (0.002 V) |
|---|---|---|---|
| Current/Power | -1.09 A (-57 W) | Runtime | 3d 13h 5m to empty |
| Remain Capacity/Energy | 92.8 Ah (4.7 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 93.2 % | State Of Health | 99.5 % |
| Temperature | 25.3 °C | Cycle | 154 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-08-23 23:56 |
| Voltage | 53.12 V | Cell (MIN/MAX) | 3.318 V / 3.321 V (0.003 V) |
|---|---|---|---|
| Current/Power | -1.11 A (-58 W) | Runtime | 3d 11h 14m to empty |
| Remain Capacity/Energy | 92.4 Ah (4.7 kWh) | Full Capacity/Energy | 99.2 Ah (5.1 kWh) |
| State Of Charge | 93.2 % | State Of Health | 99.2 % |
| Temperature | 25.9 °C | Cycle | 153 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-08-23 23:56 |