| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Importing from grid by 0.956 kW | |||
|---|---|---|---|
| 07/01/2026 22:38 (2226 days) | Production | Consumption | NET Usage |
| Now | 0.000 kW | 0.956 kW | 0.956 kW |
| Today | 25.631 kWh (1.131 kW) | 39.959 kWh (1.763 kW) | 14.328 kWh (0.632 kW) |
| - This Week | 107.232 kWh (27.192 kWh/day) | 114.099 kWh (28.933 kWh/day) | 6.867 kWh (1.741 kWh/day) |
| - This Month | 25.631 kWh (27.147 kWh/day) | 39.959 kWh (42.323 kWh/day) | 14.328 kWh (15.176 kWh/day) |
| - This Year | 3.635 MWh (19.981 kWh/day) | 3.327 MWh (18.284 kWh/day) | -0.309 MWh (-1.697 kWh/day) |
| Yesterday | 26.873 kWh (1.121 kW) | 21.329 kWh (0.889 kW) | -5.544 kWh (-0.231 kW) |
| Last 7 Days | 164.808 kWh (23.544 kWh/day) | 170.671 kWh (24.382 kWh/day) | 5.863 kWh (0.838 kWh/day) |
| Last 30 Days (06/01/2026) | 865.456 kWh (28.849 kWh/day) | 747.314 kWh (24.910 kWh/day) | -118.142 kWh (-3.938 kWh/day) |
| Last One Year | 6.700 MWh (18.355 kWh/day) | 7.728 MWh (21.172 kWh/day) | 1.028 MWh (2.817 kWh/day) |
| Lifetime Since PTO | 39.201 MWh (17.603 kW/day) | 42.838 MWh (19.236 kW/day) | 3.636 MWh (1.633 kW/day) |
| Lifetime Since Install | 39.235 MWh | 43.417 MWh | 4.182 MWh |
| Voltage/Current | 249.6 V / 0.0 A | 249.6 V / 3.8 A | 249.6 V / 3.8 A |
|
|||
| Micro-inverters [pcu_num:5, pcu_level:1] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 08/16/2025 23:56 (23.9 hours) | Number of Devices | 18 set | |||||||
| Current Power | 0.229 kW (0.013 kW/panel) | Today Energy | 29.821 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.288 | 1.715 | 1.987 | 13.028 | 0.000 kW 1.679 kWh |
0.000 kW 10.075 kWh |
| 02 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.274 | 1.639 | 1.873 | 12.258 | |||
| 03 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.286 | 1.702 | 1.956 | 12.772 | |||
| 04 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.291 | 1.738 | 2.013 | 13.106 | |||
| 05 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.276 | 1.617 | 1.791 | 11.661 | |||
| 06 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.283 | 1.664 | 1.902 | 12.455 | |||
| front | 07 - 202206****** | IQ7+ | [0] ---- | 0.000 | 0.284 | 1.666 | 1.871 | 12.287 | 0.000 kW 1.702 kWh |
0.000 kW 8.512 kWh |
| 08 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.293 | 1.707 | 1.908 | 12.259 | |||
| 09 - 202217****** | IQ7+ | [0] ---- | 0.000 | 0.292 | 1.700 | 1.900 | 12.253 | |||
| 10 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.291 | 1.704 | 1.923 | 12.462 | |||
| 11 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.295 | 1.737 | 1.964 | 12.713 | |||
| back | 12 - 202211****** | IQ7+ | [0] ---- | 0.000 | 0.236 | 1.397 | 1.758 | 11.634 | 0.000 kW 1.435 kWh |
0.000 kW 5.741 kWh |
| 13 - 202223****** | IQ7+ | [0] ---- | 0.000 | 0.242 | 1.398 | 1.765 | 11.664 | |||
| 14 - 202216****** | IQ7+ | [0] ---- | 0.000 | 0.243 | 1.465 | 1.833 | 12.123 | |||
| 15 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.246 | 1.481 | 1.842 | 12.181 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.076 kW 1.831 kWh |
0.229 kW 5.493 kWh |
| 17 - 122344****** | IQ7AS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
| 18 - 122214****** | IQ7PD | [0] ---- | 0.229 | 0.230 | 5.493 | 5.511 | 38.458 | |||
|
||||||||||
| Charger History | |||||
|---|---|---|---|---|---|
| Voltage PV | 0.93 V | Voltage Charge | 52.32 V | Current/Power | 0.00 A / 0.000 kW |
| Int/Ext Temp | 32.3 °C / 30.0 °C | Flags | 00/00/00 | Energy Today | 0.000 kWh @ 2025-08-16 23:58 |
|
|||||
| Battery History | |||
|---|---|---|---|
| Voltage | 52.60 V | Current/Power | -6.08 A (-0.320 kW) |
| Remain Capacity/Energy | 313.2 Ah (16.0 kWh) | Full Capacity/Energy | 593.1 Ah (30.4 kWh) |
| State Of Charge | 52.8 % | State Of Health | 98.9 % |
| Run Time | 2d 3h 31m to empty | Report Date | 2025-08-16 23:55 |
|
|||
| Voltage | 52.56 V | Cell (MIN/MAX) | 3.279 V / 3.289 V (0.010 V) |
|---|---|---|---|
| Current/Power | -1.84 A (-96 W) | Runtime | 2d 8h 39m to empty |
| Remain Capacity/Energy | 104.4 Ah (5.3 kWh) | Full Capacity/Energy | 197.7 Ah (10.1 kWh) |
| State Of Charge | 52.8 % | State Of Health | 98.8 % |
| Temperature | 26.5 °C | Cycle | 212 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-08-16 23:55 |
| Voltage | 52.61 V | Cell (MIN/MAX) | 3.286 V / 3.289 V (0.003 V) |
|---|---|---|---|
| Current/Power | -1.05 A (-55 W) | Runtime | 2d 18h 6m to empty |
| Remain Capacity/Energy | 69.4 Ah (3.6 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 69.8 % | State Of Health | 99.5 % |
| Temperature | 27.1 °C | Cycle | 147 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-08-16 23:57 |
| Voltage | 52.64 V | Cell (MIN/MAX) | 3.289 V / 3.291 V (0.002 V) |
|---|---|---|---|
| Current/Power | -1.07 A (-56 W) | Runtime | 2d 15h 0m to empty |
| Remain Capacity/Energy | 67.4 Ah (3.5 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 67.8 % | State Of Health | 99.5 % |
| Temperature | 26.3 °C | Cycle | 151 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-08-16 23:57 |
| Voltage | 52.60 V | Cell (MIN/MAX) | 3.286 V / 3.288 V (0.002 V) |
|---|---|---|---|
| Current/Power | -1.06 A (-55 W) | Runtime | 2d 15h 43m to empty |
| Remain Capacity/Energy | 67.5 Ah (3.5 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 67.8 % | State Of Health | 99.5 % |
| Temperature | 26.3 °C | Cycle | 153 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-08-16 23:58 |
| Voltage | 52.59 V | Cell (MIN/MAX) | 3.286 V / 3.288 V (0.002 V) |
|---|---|---|---|
| Current/Power | -1.08 A (-56 W) | Runtime | 2d 14h 0m to empty |
| Remain Capacity/Energy | 67.1 Ah (3.4 kWh) | Full Capacity/Energy | 99.2 Ah (5.1 kWh) |
| State Of Charge | 67.7 % | State Of Health | 99.2 % |
| Temperature | 27.0 °C | Cycle | 152 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-08-16 23:56 |