Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 4.294 kW
05/14/2026 14:51 (2178 days) Production Consumption NET Usage
Now 4.661 kW 0.367 kW -4.294 kW
Today 14.659 kWh (0.986 kW) 8.874 kWh (0.597 kW) -5.785 kWh (-0.389 kW)
  - This Week 121.960 kWh (26.400 kWh/day) 60.236 kWh (13.039 kWh/day) -61.724 kWh (-13.361 kWh/day)
  - This Month 340.035 kWh (24.967 kWh/day) 177.373 kWh (13.024 kWh/day) -162.662 kWh (-11.944 kWh/day)
  - This Year 2.293 MWh (17.161 kWh/day) 2.237 MWh (16.742 kWh/day) -0.056 MWh (-0.419 kWh/day)
Yesterday 25.506 kWh (1.062 kW) 14.443 kWh (0.601 kW) -11.063 kWh (-0.461 kW)
Last 7 Days 163.702 kWh (23.386 kWh/day) 131.566 kWh (18.795 kWh/day) -32.136 kWh (-4.591 kWh/day)
Last 30 Days (04/14/2026) 698.621 kWh (23.287 kWh/day) 427.347 kWh (14.245 kWh/day) -271.274 kWh (-9.042 kWh/day)
Last One Year 6.323 MWh (17.322 kWh/day) 7.795 MWh (21.356 kWh/day) 1.472 MWh (4.034 kWh/day)
Lifetime Since PTO 37.859 MWh (17.377 kW/day) 41.748 MWh (19.163 kW/day) 3.889 MWh (1.785 kW/day)
Lifetime Since Install 37.893 MWh 42.328 MWh 4.435 MWh
Voltage/Current 252.7 V / 18.4 A 252.7 V / 1.5 A 252.7 V / -17.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/27/2025 23:24 (14.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 12.040 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.207 0.838 0.774 12.055 0.000 kW
0.819 kWh
0.000 kW
4.912 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.200 0.803 0.742 11.261
03 - 202224****** IQ7+M [5] VCOP 0.000 0.203 0.830 0.764 11.375
04 - 202232****** IQ7+ [5] VCOP 0.000 0.208 0.830 0.763 11.556
05 - 202244****** IQ7+M [5] VCOP 0.000 0.197 0.788 0.726 10.246
06 - 202245****** IQ7+M [5] VCOP 0.000 0.202 0.822 0.762 11.662
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.192 0.768 0.715 10.795 0.000 kW
0.766 kWh
0.000 kW
3.831 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.192 0.765 0.708 10.536
09 - 202217****** IQ7+ [5] VCOP 0.000 0.190 0.770 0.714 10.675
10 - 202244****** IQ7+M [5] VCOP 0.000 0.192 0.770 0.714 10.795
11 - 202224****** IQ7+M [5] VCOP 0.000 0.194 0.758 0.696 10.869
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.189 0.762 0.734 11.649 0.000 kW
0.824 kWh
0.000 kW
3.297 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.189 0.804 0.773 11.731
14 - 202216****** IQ7+ [5] VCOP 0.000 0.199 0.861 0.838 12.181
15 - 202245****** IQ7+M [5] VCOP 0.000 0.200 0.870 0.847 12.235
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Charger History
Voltage PV 1.63 V Voltage Charge 52.26 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 30.5 °C / 27.7 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-06-27 23:58
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.52 V Current/Power -6.38 A (-0.335 kW)
Remain Capacity/Energy 345.3 Ah (17.7 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 58.2 % State Of Health 98.9 %
Run Time 2d 6h 7m to empty Report Date 2025-06-27 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.