Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.029 kW
09/10/2025 08:17 (1932 days) Production Consumption NET Usage
Now 0.273 kW 0.302 kW 0.029 kW
Today 0.131 kWh (0.016 kW) 2.891 kWh (0.349 kW) 2.760 kWh (0.333 kW)
  - This Week 65.328 kWh (19.525 kWh/day) 45.266 kWh (13.529 kWh/day) -20.062 kWh (-5.996 kWh/day)
  - This Month 202.256 kWh (21.642 kWh/day) 240.991 kWh (25.787 kWh/day) 38.735 kWh (4.145 kWh/day)
  - This Year 4.710 MWh (18.663 kWh/day) 5.412 MWh (21.446 kWh/day) 0.702 MWh (2.782 kWh/day)
Yesterday 26.560 kWh (1.106 kW) 8.481 kWh (0.353 kW) -18.079 kWh (-0.753 kW)
Last 7 Days 153.188 kWh (21.880 kWh/day) 171.276 kWh (24.463 kWh/day) 18.088 kWh (2.583 kWh/day)
Last 30 Days 701.849 kWh (23.395 kWh/day) 805.275 kWh (26.842 kWh/day) 103.426 kWh (3.448 kWh/day)
Last One Year 6.292 MWh (17.238 kWh/day) 7.076 MWh (19.386 kWh/day) 0.784 MWh (2.147 kWh/day)
Lifetime Since PTO 34.160 MWh (17.678 kW/day) 37.364 MWh (19.336 kW/day) 3.203 MWh (1.658 kW/day)
Lifetime Since Install 34.194 MWh 37.944 MWh 3.749 MWh
Voltage/Current 252.4 V / 1.1 A 252.3 V / 1.2 A 252.4 V / 0.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/04/2024 23:55 (23.9 hours) Number of Devices 16 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 31.917 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.259 1.850 1.986 8.813 0.000 kW
1.796 kWh
0.000 kW
10.775 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.247 1.766 1.890 8.366
03 - 202224****** IQ7+M [5] VCOP 0.000 0.256 1.847 1.968 8.684
04 - 202232****** IQ7+ [5] VCOP 0.000 0.260 1.878 1.996 8.747
05 - 202244****** IQ7+M [5] VCOP 0.000 0.246 1.695 1.823 8.214
06 - 202245****** IQ7+M [5] VCOP 0.000 0.252 1.740 1.876 8.467
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.267 1.822 1.969 8.689 0.000 kW
1.875 kWh
0.000 kW
9.374 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.269 1.884 2.017 8.712
09 - 202217****** IQ7+ [5] VCOP 0.000 0.267 1.845 1.965 8.593
10 - 202244****** IQ7+M [5] VC-- 0.000 0.264 1.893 2.027 8.765
11 - 202224****** IQ7+M [5] VC-- 0.000 0.270 1.930 2.072 8.907
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.205 1.509 1.592 6.957 0.000 kW
1.569 kWh
0.000 kW
6.276 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.213 1.540 1.621 7.150
14 - 202216****** IQ7+ [5] VCOP 0.000 0.217 1.616 1.698 7.512
15 - 202245****** IQ7+M [5] VCOP 0.000 0.216 1.611 1.690 7.483
wind 16 - 122214****** IQ7PD [5] VCOP 0.230 0.230 5.492 5.495 22.343 0.230 kW
5.492 kWh
0.230 kW
5.492 kWh
Panel Layout Each Group Production

Charger History
Voltage PV 0.58 V Voltage Charge 52.85 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 30.8 °C / 28.1 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2024-09-04 23:58
voltage in/out power and energy internal/external temperature

Battery History
Voltage 53.13 V Current/Power -6.27 A (-0.333 kW)
Remain Capacity/Energy 413.6 Ah (21.2 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 69.7 % State Of Health 98.9 %
Run Time 2d 17h 57m to empty Report Date 2024-09-04 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.