Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.048 kW
05/14/2026 19:36 (2178 days) Production Consumption NET Usage
Now 0.381 kW 0.429 kW 0.048 kW
Today 20.877 kWh (1.064 kW) 11.951 kWh (0.609 kW) -8.926 kWh (-0.455 kW)
  - This Week 128.178 kWh (26.607 kWh/day) 63.313 kWh (13.142 kWh/day) -64.865 kWh (-13.465 kWh/day)
  - This Month 346.253 kWh (25.060 kWh/day) 180.450 kWh (13.060 kWh/day) -165.803 kWh (-12.000 kWh/day)
  - This Year 2.299 MWh (17.182 kWh/day) 2.240 MWh (16.740 kWh/day) -0.059 MWh (-0.442 kWh/day)
Yesterday 25.506 kWh (1.062 kW) 14.443 kWh (0.601 kW) -11.063 kWh (-0.461 kW)
Last 7 Days 159.035 kWh (22.719 kWh/day) 133.060 kWh (19.009 kWh/day) -25.975 kWh (-3.711 kWh/day)
Last 30 Days (04/14/2026) 694.872 kWh (23.162 kWh/day) 420.062 kWh (14.002 kWh/day) -274.810 kWh (-9.160 kWh/day)
Last One Year 6.328 MWh (17.337 kWh/day) 7.794 MWh (21.354 kWh/day) 1.466 MWh (4.017 kWh/day)
Lifetime Since PTO 37.865 MWh (17.379 kW/day) 41.751 MWh (19.162 kW/day) 3.886 MWh (1.784 kW/day)
Lifetime Since Install 37.899 MWh 42.331 MWh 4.432 MWh
Voltage/Current 251.3 V / 1.5 A 251.4 V / 1.7 A 251.3 V / 0.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/19/2025 23:44 (12.7 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 18.414 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.274 1.306 1.926 8.646 0.000 kW
1.273 kWh
0.000 kW
7.637 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.261 1.242 1.829 8.265
03 - 202224****** IQ7+M [5] VCOP 0.000 0.272 1.288 1.920 8.178
04 - 202232****** IQ7+ [5] VCOP 0.000 0.269 1.296 1.977 8.862
05 - 202244****** IQ7+M [5] VCOP 0.000 0.262 1.236 1.733 8.359
06 - 202245****** IQ7+M [5] VCOP 0.000 0.270 1.268 1.818 8.490
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.285 1.302 1.758 8.812 0.000 kW
1.310 kWh
0.000 kW
6.552 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.285 1.307 1.826 8.603
09 - 202217****** IQ7+ [5] VCOP 0.000 0.283 1.305 1.821 8.624
10 - 202244****** IQ7+M [5] VCOP 0.000 0.277 1.311 1.824 8.657
11 - 202224****** IQ7+M [5] VCOP 0.000 0.280 1.328 1.847 8.962
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.227 1.026 1.801 7.796 0.000 kW
1.056 kWh
0.000 kW
4.225 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.231 1.045 1.843 8.085
14 - 202216****** IQ7+ [5] VCOP 0.000 0.232 1.078 1.880 8.293
15 - 202245****** IQ7+M [5] VCOP 0.000 0.231 1.076 1.884 8.267
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VC-- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Charger History
Voltage PV 0.48 V Voltage Charge 52.13 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 28.6 °C / 25.6 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-04-19 23:58
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.39 V Current/Power -11.30 A (-0.592 kW)
Remain Capacity/Energy 275.2 Ah (14.1 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 46.4 % State Of Health 98.9 %
Run Time 1d 0h 21m to empty Report Date 2025-04-19 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack


Warning: unlink(images/chart_batt1_0.png): No such file or directory in C:\wamp64\www\solar\chart_batteries.php on line 185
JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.