Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.473 kW
11/05/2025 03:34 (1988 days) Production Consumption NET Usage
Now 0.000 kW 0.473 kW 0.473 kW
Today 0.000 kWh (0.000 kW) 1.464 kWh (0.410 kW) 1.464 kWh (0.410 kW)
  - This Week 41.380 kWh (13.140 kWh/day) 58.078 kWh (18.443 kWh/day) 16.698 kWh (5.302 kWh/day)
  - This Month 58.318 kWh (14.054 kWh/day) 74.266 kWh (17.898 kWh/day) 15.948 kWh (3.843 kWh/day)
  - This Year 5.636 MWh (18.291 kWh/day) 6.407 MWh (20.791 kWh/day) 0.770 MWh (2.500 kWh/day)
Yesterday 17.563 kWh (0.731 kW) 16.185 kWh (0.674 kW) -1.378 kWh (-0.057 kW)
Last 7 Days 82.342 kWh (11.763 kWh/day) 113.017 kWh (16.145 kWh/day) 30.675 kWh (4.382 kWh/day)
Last 30 Days 421.814 kWh (14.060 kWh/day) 474.278 kWh (15.809 kWh/day) 52.464 kWh (1.749 kWh/day)
Last One Year 6.196 MWh (16.976 kWh/day) 7.440 MWh (20.382 kWh/day) 1.243 MWh (3.407 kWh/day)
Lifetime Since PTO 35.087 MWh (17.648 kW/day) 38.359 MWh (19.294 kW/day) 3.272 MWh (1.646 kW/day)
Lifetime Since Install 35.121 MWh 38.939 MWh 3.818 MWh
Voltage/Current 251.3 V / 0.0 A 251.1 V / 1.9 A 251.2 V / 1.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/11/2024 23:36 (6.4 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 34.348 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.247 2.477 0.568 9.007 0.000 kW
2.408 kWh
0.000 kW
14.448 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.235 2.358 0.537 8.572
03 - 202224****** IQ7+M [0] ---- 0.000 0.241 2.417 0.554 8.846
04 - 202232****** IQ7+ [0] ---- 0.000 0.242 2.411 0.553 8.892
05 - 202244****** IQ7+M [0] ---- 0.000 0.235 2.373 0.519 8.451
06 - 202245****** IQ7+M [0] ---- 0.000 0.239 2.412 0.530 8.606
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.278 2.769 0.319 8.572 0.000 kW
2.776 kWh
0.000 kW
13.880 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.280 2.791 0.465 9.476
09 - 202217****** IQ7+ [0] ---- 0.000 0.279 2.765 0.530 9.624
10 - 202244****** IQ7+M [0] ---- 0.000 0.276 2.753 0.526 9.643
11 - 202224****** IQ7+M [0] ---- 0.000 0.282 2.803 0.521 9.751
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.159 1.420 0.523 5.921 0.000 kW
1.505 kWh
0.000 kW
6.020 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.164 1.511 0.539 6.283
14 - 202216****** IQ7+ [0] ---- 0.000 0.168 1.553 0.555 6.531
15 - 202245****** IQ7+M [0] ---- 0.000 0.166 1.536 0.552 6.485
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 10.547 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Charger History
Voltage PV 0.55 V Voltage Charge 52.97 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 26.5 °C / 25.0 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2024-10-11 23:58
voltage in/out power and energy internal/external temperature

Battery History
Voltage 53.18 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 520.8 Ah (26.7 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 87.8 % State Of Health 98.9 %
Run Time 14d 11h 11m to empty Report Date 2024-10-11 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.