Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.293 kW
03/10/2026 03:39 (2113 days) Production Consumption NET Usage
Now 0.000 kW 0.293 kW 0.293 kW
Today 0.000 kWh (0.000 kW) 1.252 kWh (0.342 kW) 1.252 kWh (0.342 kW)
  - This Week 36.181 kWh (16.807 kWh/day) 28.926 kWh (13.437 kWh/day) -7.255 kWh (-3.370 kWh/day)
  - This Month 129.889 kWh (14.192 kWh/day) 135.225 kWh (14.775 kWh/day) 5.336 kWh (0.583 kWh/day)
  - This Year 0.764 MWh (11.207 kWh/day) 1.235 MWh (18.122 kWh/day) 0.471 MWh (6.915 kWh/day)
Yesterday 25.455 kWh (1.061 kW) 15.204 kWh (0.633 kW) -10.251 kWh (-0.427 kW)
Last 7 Days 78.873 kWh (11.268 kWh/day) 106.106 kWh (15.158 kWh/day) 27.233 kWh (3.890 kWh/day)
Last 30 Days 405.705 kWh (13.524 kWh/day) 507.394 kWh (16.913 kWh/day) 101.689 kWh (3.390 kWh/day)
Last One Year 6.066 MWh (16.620 kWh/day) 7.802 MWh (21.376 kWh/day) 1.736 MWh (4.756 kWh/day)
Lifetime Since PTO 36.329 MWh (17.192 kW/day) 40.746 MWh (19.282 kW/day) 4.416 MWh (2.090 kW/day)
Lifetime Since Install 36.363 MWh 41.326 MWh 4.962 MWh
Voltage/Current 249.8 V / 0.0 A 249.9 V / 1.2 A 249.9 V / 1.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/15/2025 23:07 (9.3 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.804 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.251 1.099 1.096 5.760 0.000 kW
1.076 kWh
0.000 kW
6.456 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.244 1.058 1.036 5.470
03 - 202224****** IQ7+M [0] ---- 0.000 0.252 1.097 1.076 5.732
04 - 202232****** IQ7+ [0] ---- 0.000 0.253 1.074 1.080 5.788
05 - 202244****** IQ7+M [0] ---- 0.000 0.248 1.070 1.042 5.545
06 - 202245****** IQ7+M [0] ---- 0.000 0.248 1.058 1.063 5.626
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.296 1.085 1.123 6.200 0.000 kW
1.244 kWh
0.000 kW
6.221 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.296 1.236 1.278 6.892
09 - 202217****** IQ7+ [0] ---- 0.000 0.296 1.340 1.361 7.327
10 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.331 1.339 7.239
11 - 202224****** IQ7+M [0] ---- 0.000 0.297 1.229 1.269 6.845
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.127 0.484 0.407 2.287 0.000 kW
0.532 kWh
0.000 kW
2.127 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.136 0.543 0.491 2.679
14 - 202216****** IQ7+ [0] ---- 0.000 0.137 0.557 0.507 2.778
15 - 202245****** IQ7+M [0] ---- 0.000 0.137 0.542 0.498 2.746
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Charger History
Voltage PV 0.76 V Voltage Charge 52.79 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 26.8 °C / 23.6 °C Flags 00/00/00 Energy Today 6.009 kWh @ 2025-01-15 23:57
voltage in/out power and energy internal/external temperature

Battery History
Voltage 53.04 V Current/Power -6.24 A (-0.331 kW)
Remain Capacity/Energy 390.9 Ah (20.0 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 65.9 % State Of Health 98.9 %
Run Time 2d 14h 38m to empty Report Date 2025-01-15 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.