Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.262 kW
03/10/2026 05:21 (2113 days) Production Consumption NET Usage
Now 0.000 kW 0.262 kW 0.262 kW
Today 0.000 kWh (0.000 kW) 1.778 kWh (0.332 kW) 1.778 kWh (0.332 kW)
  - This Week 36.181 kWh (16.272 kWh/day) 29.452 kWh (13.246 kWh/day) -6.729 kWh (-3.026 kWh/day)
  - This Month 129.889 kWh (14.083 kWh/day) 135.751 kWh (14.718 kWh/day) 5.862 kWh (0.636 kWh/day)
  - This Year 0.764 MWh (11.196 kWh/day) 1.236 MWh (18.111 kWh/day) 0.472 MWh (6.915 kWh/day)
Yesterday 25.455 kWh (1.061 kW) 15.204 kWh (0.633 kW) -10.251 kWh (-0.427 kW)
Last 7 Days 78.338 kWh (11.191 kWh/day) 106.060 kWh (15.151 kWh/day) 27.722 kWh (3.960 kWh/day)
Last 30 Days 405.168 kWh (13.506 kWh/day) 506.746 kWh (16.892 kWh/day) 101.578 kWh (3.386 kWh/day)
Last One Year 6.066 MWh (16.620 kWh/day) 7.802 MWh (21.375 kWh/day) 1.736 MWh (4.755 kWh/day)
Lifetime Since PTO 36.329 MWh (17.192 kW/day) 40.746 MWh (19.282 kW/day) 4.417 MWh (2.090 kW/day)
Lifetime Since Install 36.363 MWh 41.326 MWh 4.963 MWh
Voltage/Current 248.9 V / 0.0 A 249.0 V / 1.1 A 249.0 V / 1.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/18/2024 23:15 (8.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 11.655 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.199 0.875 0.742 4.626 0.000 kW
0.858 kWh
0.000 kW
5.148 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.188 0.836 0.711 4.409
03 - 202224****** IQ7+M [0] ---- 0.000 0.195 0.871 0.745 4.622
04 - 202232****** IQ7+ [0] ---- 0.000 0.190 0.878 0.755 4.666
05 - 202244****** IQ7+M [0] ---- 0.000 0.183 0.840 0.722 4.444
06 - 202245****** IQ7+M [0] ---- 0.000 0.193 0.848 0.724 4.474
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.265 0.884 0.955 4.953 0.000 kW
1.013 kWh
0.000 kW
5.065 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.260 1.027 0.963 5.544
09 - 202217****** IQ7+ [0] ---- 0.000 0.250 1.093 0.978 5.828
10 - 202244****** IQ7+M [0] ---- 0.000 0.257 1.071 0.973 5.737
11 - 202224****** IQ7+M [0] ---- 0.000 0.250 0.990 0.984 5.482
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.070 0.316 0.232 1.702 0.000 kW
0.361 kWh
0.000 kW
1.442 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.082 0.371 0.282 2.057
14 - 202216****** IQ7+ [0] ---- 0.000 0.087 0.384 0.294 2.157
15 - 202245****** IQ7+M [0] ---- 0.000 0.084 0.372 0.290 2.123
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Charger History
Voltage PV 2.09 V Voltage Charge 52.73 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 26.6 °C / 23.8 °C Flags 00/00/00 Energy Today 4.692 kWh @ 2024-12-18 23:55
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.92 V Current/Power -1.74 A (-92 W)
Remain Capacity/Energy 373.8 Ah (19.1 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 63.0 % State Of Health 98.9 %
Run Time 8d 22h 49m to empty Report Date 2024-12-18 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.