Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.197 kW
09/10/2025 16:24 (1932 days) Production Consumption NET Usage
Now 1.407 kW 0.210 kW -1.197 kW
Today 12.502 kWh (0.762 kW) 6.674 kWh (0.407 kW) -5.828 kWh (-0.355 kW)
  - This Week 77.699 kWh (21.092 kWh/day) 49.049 kWh (13.315 kWh/day) -28.650 kWh (-7.777 kWh/day)
  - This Month 214.627 kWh (22.164 kWh/day) 244.774 kWh (25.277 kWh/day) 30.147 kWh (3.113 kWh/day)
  - This Year 4.722 MWh (18.687 kWh/day) 5.416 MWh (21.432 kWh/day) 0.694 MWh (2.745 kWh/day)
Yesterday 26.560 kWh (1.106 kW) 8.481 kWh (0.353 kW) -18.079 kWh (-0.753 kW)
Last 7 Days 153.188 kWh (21.880 kWh/day) 171.276 kWh (24.463 kWh/day) 18.088 kWh (2.583 kWh/day)
Last 30 Days 701.849 kWh (23.395 kWh/day) 805.275 kWh (26.842 kWh/day) 103.426 kWh (3.448 kWh/day)
Last One Year 6.292 MWh (17.238 kWh/day) 7.076 MWh (19.386 kWh/day) 0.784 MWh (2.147 kWh/day)
Lifetime Since PTO 34.173 MWh (17.682 kW/day) 37.367 MWh (19.335 kW/day) 3.195 MWh (1.653 kW/day)
Lifetime Since Install 34.207 MWh 37.947 MWh 3.741 MWh
Voltage/Current 251.8 V / 5.6 A 251.8 V / 0.8 A 251.8 V / -4.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/10/2024 23:55 (23.9 hours) Number of Devices 16 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 28.395 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.293 1.621 1.413 12.736 0.000 kW
1.486 kWh
0.000 kW
8.919 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.291 1.490 1.355 12.021
03 - 202224****** IQ7+M [5] VCOP 0.000 0.284 1.486 1.392 12.264
04 - 202232****** IQ7+ [5] VCOP 0.000 0.293 1.519 1.395 12.467
05 - 202244****** IQ7+M [5] VCOP 0.000 0.287 1.262 1.348 11.166
06 - 202245****** IQ7+M [5] VCOP 0.000 0.293 1.541 1.378 12.287
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.282 1.373 1.392 11.688 0.000 kW
1.368 kWh
0.000 kW
6.838 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.291 1.326 1.275 11.285
09 - 202217****** IQ7+ [5] VCOP 0.000 0.279 1.338 1.335 11.399
10 - 202244****** IQ7+M [5] VCOP 0.000 0.286 1.388 1.405 11.674
11 - 202224****** IQ7+M [5] VCOP 0.000 0.281 1.412 1.437 11.923
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.291 1.730 1.061 11.391 0.000 kW
1.786 kWh
0.000 kW
7.142 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.293 1.756 1.015 11.449
14 - 202216****** IQ7+ [5] VCOP 0.000 0.293 1.836 1.142 12.149
15 - 202245****** IQ7+M [5] VCOP 0.000 0.291 1.820 1.129 12.094
wind 16 - 122214****** IQ7PD [5] VCOP 0.230 0.230 5.496 5.492 38.462 0.230 kW
5.496 kWh
0.230 kW
5.496 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.10 V Current/Power -6.11 A (-0.324 kW)
Remain Capacity/Energy 388.0 Ah (19.9 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 65.4 % State Of Health 98.9 %
Run Time 2d 15h 29m to empty Report Date 2024-06-10 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.