Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.378 kW
09/10/2025 20:31 (1932 days) Production Consumption NET Usage
Now 0.000 kW 0.378 kW 0.378 kW
Today 13.894 kWh (0.677 kW) 9.419 kWh (0.459 kW) -4.475 kWh (-0.218 kW)
  - This Week 79.091 kWh (20.512 kWh/day) 51.794 kWh (13.433 kWh/day) -27.297 kWh (-7.079 kWh/day)
  - This Month 216.019 kWh (21.918 kWh/day) 247.519 kWh (25.115 kWh/day) 31.500 kWh (3.196 kWh/day)
  - This Year 4.723 MWh (18.680 kWh/day) 5.418 MWh (21.428 kWh/day) 0.695 MWh (2.748 kWh/day)
Yesterday 26.560 kWh (1.106 kW) 8.481 kWh (0.353 kW) -18.079 kWh (-0.753 kW)
Last 7 Days 153.188 kWh (21.880 kWh/day) 171.276 kWh (24.463 kWh/day) 18.088 kWh (2.583 kWh/day)
Last 30 Days 701.849 kWh (23.395 kWh/day) 805.275 kWh (26.842 kWh/day) 103.426 kWh (3.448 kWh/day)
Last One Year 6.292 MWh (17.238 kWh/day) 7.076 MWh (19.386 kWh/day) 0.784 MWh (2.147 kWh/day)
Lifetime Since PTO 34.174 MWh (17.681 kW/day) 37.370 MWh (19.334 kW/day) 3.196 MWh (1.654 kW/day)
Lifetime Since Install 34.208 MWh 37.950 MWh 3.742 MWh
Voltage/Current 252.0 V / 0.0 A 252.0 V / 1.5 A 252.0 V / 1.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/23/2024 23:27 (14.4 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 19.644 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.290 1.395 2.207 11.116 0.000 kW
1.352 kWh
0.000 kW
8.113 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.280 1.326 2.052 10.468
03 - 202224****** IQ7+M [0] ---- 0.000 0.288 1.372 2.106 10.801
04 - 202232****** IQ7+ [0] ---- 0.000 0.289 1.377 2.171 11.005
05 - 202244****** IQ7+M [0] ---- 0.000 0.280 1.299 1.885 9.805
06 - 202245****** IQ7+M [0] ---- 0.000 0.286 1.344 2.110 10.683
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.287 1.311 2.040 10.203 0.000 kW
1.310 kWh
0.000 kW
6.552 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.293 1.298 2.000 10.021
09 - 202217****** IQ7+ [0] ---- 0.000 0.285 1.294 2.006 10.028
10 - 202244****** IQ7+M [0] ---- 0.000 0.283 1.311 2.019 10.144
11 - 202224****** IQ7+M [0] ---- 0.000 0.289 1.338 2.072 10.359
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.230 1.185 2.051 10.128 0.000 kW
1.245 kWh
0.000 kW
4.980 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.241 1.228 2.051 10.263
14 - 202216****** IQ7+ [0] ---- 0.000 0.242 1.285 2.162 10.857
15 - 202245****** IQ7+M [0] ---- 0.000 0.240 1.281 2.166 10.853
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.50 V Current/Power -4.90 A (-0.257 kW)
Remain Capacity/Energy 265.8 Ah (13.6 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 44.8 % State Of Health 98.9 %
Run Time 2d 6h 14m to empty Report Date 2024-05-23 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.