Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.431 kW
11/03/2025 11:15 (1986 days) Production Consumption NET Usage
Now 0.758 kW 0.327 kW -0.431 kW
Today 3.695 kWh (0.328 kW) 3.755 kWh (0.333 kW) 0.060 kWh (0.005 kW)
  - This Week 20.866 kWh (14.203 kWh/day) 30.072 kWh (20.469 kWh/day) 9.206 kWh (6.266 kWh/day)
  - This Month 37.804 kWh (15.308 kWh/day) 46.260 kWh (18.732 kWh/day) 8.456 kWh (3.424 kWh/day)
  - This Year 5.616 MWh (18.324 kWh/day) 6.379 MWh (20.813 kWh/day) 0.763 MWh (2.489 kWh/day)
Yesterday 17.171 kWh (0.716 kW) 26.317 kWh (1.097 kW) 9.146 kWh (0.381 kW)
Last 7 Days 86.148 kWh (12.307 kWh/day) 98.955 kWh (14.137 kWh/day) 12.807 kWh (1.830 kWh/day)
Last 30 Days 441.432 kWh (14.715 kWh/day) 484.805 kWh (16.161 kWh/day) 43.373 kWh (1.446 kWh/day)
Last One Year 6.208 MWh (17.008 kWh/day) 7.431 MWh (20.358 kWh/day) 1.223 MWh (3.350 kWh/day)
Lifetime Since PTO 35.067 MWh (17.652 kW/day) 38.331 MWh (19.296 kW/day) 3.265 MWh (1.643 kW/day)
Lifetime Since Install 35.101 MWh 38.911 MWh 3.811 MWh
Voltage/Current 249.2 V / 3.0 A 249.2 V / 1.3 A 249.2 V / -1.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:1, pcu_level:5]
Recent Report Data/Time 09/13/2025 23:54 (23.9 hours) Number of Devices 16 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 27.913 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.266 1.582 1.484 9.963 0.000 kW
1.551 kWh
0.000 kW
9.309 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.257 1.519 1.412 9.534
03 - 202224****** IQ7+M [5] VCOP 0.000 0.264 1.578 1.463 9.927
04 - 202232****** IQ7+ [5] VCOP 0.000 0.270 1.605 1.479 10.016
05 - 202244****** IQ7+M [5] VCOP 0.000 0.257 1.495 1.406 9.288
06 - 202245****** IQ7+M [5] VCOP 0.000 0.260 1.530 1.447 9.529
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.278 1.528 1.561 9.701 0.000 kW
1.607 kWh
0.000 kW
8.034 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.278 1.624 1.578 10.137
09 - 202217****** IQ7+ [5] VCOP 0.000 0.290 1.616 1.564 10.002
10 - 202244****** IQ7+M [5] VCOP 0.000 0.288 1.623 1.573 10.206
11 - 202224****** IQ7+M [5] VCOP 0.000 0.286 1.644 1.597 10.334
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.203 1.219 1.054 8.007 0.000 kW
1.255 kWh
0.000 kW
5.020 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.204 1.230 1.069 8.136
14 - 202216****** IQ7+ [5] VCOP 0.000 0.211 1.283 1.120 8.443
15 - 202245****** IQ7+M [5] VCOP 0.000 0.212 1.287 1.120 8.450
wind 16 - 122214****** IQ7PD [0] ---- 0.230 0.230 5.550 5.501 38.467 0.230 kW
5.550 kWh
0.230 kW
5.550 kWh
Panel Layout Each Group Production

Charger History
Voltage PV 1.04 V Voltage Charge 52.83 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 31.0 °C / 28.3 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-09-13 23:57
voltage in/out power and energy internal/external temperature

Battery History
Voltage 53.11 V Current/Power -6.24 A (-0.331 kW)
Remain Capacity/Energy 392.5 Ah (20.1 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 66.2 % State Of Health 98.9 %
Run Time 2d 14h 53m to empty Report Date 2025-09-13 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.