Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.684 kW
11/05/2025 12:15 (1988 days) Production Consumption NET Usage
Now 1.896 kW 0.212 kW -1.684 kW
Today 6.645 kWh (0.542 kW) 6.311 kWh (0.515 kW) -0.334 kWh (-0.027 kW)
  - This Week 48.025 kWh (13.678 kWh/day) 62.925 kWh (17.921 kWh/day) 14.900 kWh (4.244 kWh/day)
  - This Month 64.963 kWh (14.399 kWh/day) 79.113 kWh (17.536 kWh/day) 14.150 kWh (3.136 kWh/day)
  - This Year 5.643 MWh (18.291 kWh/day) 6.411 MWh (20.782 kWh/day) 0.769 MWh (2.491 kWh/day)
Yesterday 17.563 kWh (0.731 kW) 16.185 kWh (0.674 kW) -1.378 kWh (-0.057 kW)
Last 7 Days 82.342 kWh (11.763 kWh/day) 113.017 kWh (16.145 kWh/day) 30.675 kWh (4.382 kWh/day)
Last 30 Days 421.814 kWh (14.060 kWh/day) 474.278 kWh (15.809 kWh/day) 52.464 kWh (1.749 kWh/day)
Last One Year 6.196 MWh (16.976 kWh/day) 7.440 MWh (20.382 kWh/day) 1.243 MWh (3.407 kWh/day)
Lifetime Since PTO 35.094 MWh (17.648 kW/day) 38.364 MWh (19.293 kW/day) 3.270 MWh (1.645 kW/day)
Lifetime Since Install 35.128 MWh 38.944 MWh 3.817 MWh
Voltage/Current 252.6 V / 7.5 A 252.7 V / 0.8 A 252.7 V / -6.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/13/2024 23:41 (14.8 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 28.712 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 2.043 1.620 11.426 0.000 kW
1.920 kWh
0.000 kW
11.522 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.909 1.492 10.687
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.929 1.490 10.777
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.967 1.518 10.965
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.718 1.280 9.631
06 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.956 1.543 10.984
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.833 1.384 10.146 0.000 kW
1.807 kWh
0.000 kW
9.036 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.748 1.368 9.754
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.781 1.360 9.889
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.819 1.404 10.198
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.855 1.432 10.403
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.275 1.976 1.735 10.908 0.000 kW
2.038 kWh
0.000 kW
8.154 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.283 1.980 1.790 10.991
14 - 202216****** IQ7+ [5] VCOP 0.000 0.286 2.100 1.858 11.622
15 - 202245****** IQ7+M [5] VCOP 0.000 0.288 2.097 1.806 11.493
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 1.426 34.377 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.22 V Current/Power -2.88 A (-0.153 kW)
Remain Capacity/Energy 492.3 Ah (25.2 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 83.0 % State Of Health 98.9 %
Run Time 7d 2h 56m to empty Report Date 2024-06-13 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.