Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.204 kW
07/02/2026 06:59 (2227 days) Production Consumption NET Usage
Now 0.662 kW 0.458 kW -0.204 kW
Today 1.668 kWh (0.238 kW) 9.345 kWh (1.331 kW) 7.677 kWh (1.094 kW)
  - This Week 108.900 kWh (25.377 kWh/day) 125.636 kWh (29.277 kWh/day) 16.736 kWh (3.900 kWh/day)
  - This Month 27.299 kWh (21.130 kWh/day) 51.496 kWh (39.859 kWh/day) 24.197 kWh (18.729 kWh/day)
  - This Year 3.637 MWh (19.952 kWh/day) 3.338 MWh (18.313 kWh/day) -0.299 MWh (-1.639 kWh/day)
Yesterday 25.631 kWh (1.069 kW) 42.151 kWh (1.757 kW) 16.520 kWh (0.689 kW)
Last 7 Days 166.138 kWh (23.734 kWh/day) 177.915 kWh (25.416 kWh/day) 11.777 kWh (1.682 kWh/day)
Last 30 Days (06/02/2026) 864.103 kWh (28.803 kWh/day) 755.467 kWh (25.182 kWh/day) -108.636 kWh (-3.621 kWh/day)
Last One Year 6.701 MWh (18.359 kWh/day) 7.733 MWh (21.186 kWh/day) 1.032 MWh (2.826 kWh/day)
Lifetime Since PTO 39.203 MWh (17.601 kW/day) 42.849 MWh (19.238 kW/day) 3.646 MWh (1.637 kW/day)
Lifetime Since Install 39.237 MWh 43.429 MWh 4.192 MWh
Voltage/Current 248.6 V / 2.7 A 248.5 V / 1.8 A 248.5 V / -0.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/22/2025 23:06 (7.2 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 0.679 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.007 0.030 0.014 3.062 0.000 kW
0.027 kWh
0.000 kW
0.161 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.006 0.025 0.010 2.892
03 - 202224****** IQ7+M [5] VCOP 0.000 0.006 0.027 0.013 3.021
04 - 202232****** IQ7+ [5] VCOP 0.000 0.007 0.030 0.014 3.001
05 - 202244****** IQ7+M [5] VCOP 0.000 0.006 0.025 0.011 2.886
06 - 202245****** IQ7+M [5] VCOP 0.000 0.006 0.024 0.010 2.932
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.035 0.100 0.031 3.007 0.000 kW
0.093 kWh
0.000 kW
0.467 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.022 0.076 0.035 3.348
09 - 202217****** IQ7+ [5] VCOP 0.000 0.020 0.092 0.037 3.554
10 - 202244****** IQ7+M [5] VCOP 0.000 0.024 0.098 0.034 3.519
11 - 202224****** IQ7+M [5] VCOP 0.000 0.024 0.103 0.037 3.325
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.002 0.008 0.006 1.674 0.000 kW
0.013 kWh
0.000 kW
0.051 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.003 0.011 0.007 1.855
14 - 202216****** IQ7+ [5] VCOP 0.000 0.004 0.014 0.012 1.943
15 - 202245****** IQ7+M [5] VCOP 0.000 0.004 0.017 0.013 1.920
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Charger History
Voltage PV 0.41 V Voltage Charge 53.12 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 23.0 °C / 20.3 °C Flags 00/00/00 Energy Today 6.664 kWh @ 2025-01-22 23:59
voltage in/out power and energy internal/external temperature

Battery History
Voltage 53.30 V Current/Power -1.62 A (-86 W)
Remain Capacity/Energy 411.0 Ah (21.0 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 69.3 % State Of Health 98.9 %
Run Time 10d 13h 42m to empty Report Date 2025-01-22 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.