Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 6.260 kW
11/05/2025 17:54 (1988 days) Production Consumption NET Usage
Now 0.000 kW 6.260 kW 6.260 kW
Today 13.117 kWh (0.732 kW) 31.232 kWh (1.744 kW) 18.115 kWh (1.012 kW)
  - This Week 54.497 kWh (14.547 kWh/day) 87.846 kWh (23.448 kWh/day) 33.349 kWh (8.902 kWh/day)
  - This Month 71.435 kWh (15.049 kWh/day) 104.034 kWh (21.917 kWh/day) 32.599 kWh (6.868 kWh/day)
  - This Year 5.649 MWh (18.298 kWh/day) 6.436 MWh (20.847 kWh/day) 0.787 MWh (2.549 kWh/day)
Yesterday 17.563 kWh (0.731 kW) 16.185 kWh (0.674 kW) -1.378 kWh (-0.057 kW)
Last 7 Days 82.342 kWh (11.763 kWh/day) 113.017 kWh (16.145 kWh/day) 30.675 kWh (4.382 kWh/day)
Last 30 Days 421.814 kWh (14.060 kWh/day) 474.278 kWh (15.809 kWh/day) 52.464 kWh (1.749 kWh/day)
Last One Year 6.196 MWh (16.976 kWh/day) 7.440 MWh (20.382 kWh/day) 1.243 MWh (3.407 kWh/day)
Lifetime Since PTO 35.100 MWh (17.649 kW/day) 38.389 MWh (19.303 kW/day) 3.289 MWh (1.654 kW/day)
Lifetime Since Install 35.134 MWh 38.969 MWh 3.835 MWh
Voltage/Current 247.5 V / 0.0 A 247.6 V / 25.3 A 247.6 V / 25.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/30/2024 23:57 (18.4 hours) Number of Devices 16 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 16.715 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.277 1.176 1.652 13.371 0.000 kW
1.145 kWh
0.000 kW
6.870 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.264 1.119 1.550 12.672
03 - 202224****** IQ7+M [0] ---- 0.000 0.272 1.164 1.611 13.169
04 - 202232****** IQ7+ [0] ---- 0.000 0.276 1.167 1.650 13.405
05 - 202244****** IQ7+M [0] V--- 0.000 0.260 1.105 1.443 12.027
06 - 202245****** IQ7+M [0] V--- 0.000 0.268 1.138 1.562 12.743
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.293 1.182 1.515 12.722 0.000 kW
1.174 kWh
0.000 kW
5.868 kWh
08 - 202245****** IQ7+M [0] V--- 0.000 0.293 1.163 1.536 12.604
09 - 202217****** IQ7+ [0] ---- 0.000 0.287 1.156 1.524 12.520
10 - 202244****** IQ7+M [0] ---- 0.000 0.293 1.173 1.529 12.749
11 - 202224****** IQ7+M [0] ---- 0.000 0.291 1.194 1.557 13.032
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.193 0.911 1.559 11.725 0.000 kW
0.954 kWh
0.000 kW
3.815 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.197 0.911 1.595 11.892
14 - 202216****** IQ7+ [0] V--- 0.000 0.213 0.999 1.660 12.483
15 - 202245****** IQ7+M [0] V--- 0.000 0.205 0.994 1.657 12.454
wind 16 - 122214****** IQ7PD [0] ---- 0.230 0.230 0.162 0.000 0.416 0.230 kW
0.162 kWh
0.230 kW
0.162 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.15 V Current/Power -6.36 A (-0.338 kW)
Remain Capacity/Energy 436.2 Ah (22.3 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 73.5 % State Of Health 98.9 %
Run Time 2d 20h 35m to empty Report Date 2024-04-30 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.