Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.861 kW
01/12/2026 18:11 (2056 days) Production Consumption NET Usage
Now 0.000 kW 0.861 kW 0.861 kW
Today 14.545 kWh (0.799 kW) 11.304 kWh (0.621 kW) -3.241 kWh (-0.178 kW)
  - This Week 24.039 kWh (13.674 kWh/day) 27.116 kWh (15.424 kWh/day) 3.077 kWh (1.750 kWh/day)
  - This Month 99.850 kWh (8.492 kWh/day) 225.850 kWh (19.207 kWh/day) 126.000 kWh (10.716 kWh/day)
  - This Year 0.100 MWh (8.492 kWh/day) 0.226 MWh (19.207 kWh/day) 0.126 MWh (10.716 kWh/day)
Yesterday 9.494 kWh (0.396 kW) 15.812 kWh (0.659 kW) 6.318 kWh (0.263 kW)
Last 7 Days 48.464 kWh (6.923 kWh/day) 153.502 kWh (21.928 kWh/day) 105.038 kWh (15.005 kWh/day)
Last 30 Days 215.151 kWh (7.171 kWh/day) 655.728 kWh (21.857 kWh/day) 440.577 kWh (14.685 kWh/day)
Last One Year 6.095 MWh (16.700 kWh/day) 7.512 MWh (20.582 kWh/day) 1.417 MWh (3.882 kWh/day)
Lifetime Since PTO 35.666 MWh (17.340 kW/day) 39.737 MWh (19.320 kW/day) 4.072 MWh (1.980 kW/day)
Lifetime Since Install 35.699 MWh 40.317 MWh 4.618 MWh
Voltage/Current 248.8 V / 0.0 A 248.8 V / 3.5 A 248.8 V / 3.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/27/2024 23:43 (14.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 26.932 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.296 1.946 1.834 13.084 0.000 kW
1.818 kWh
0.000 kW
10.908 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.823 1.736 12.237
03 - 202224****** IQ7+M [0] ---- 0.000 0.296 1.822 1.781 12.448
04 - 202232****** IQ7+ [0] ---- 0.000 0.296 1.853 1.799 12.650
05 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.589 1.609 11.112
06 - 202245****** IQ7+M [0] ---- 0.000 0.296 1.874 1.773 12.559
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.296 1.710 1.676 11.654 0.000 kW
1.699 kWh
0.000 kW
8.495 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.296 1.666 1.653 11.422
09 - 202217****** IQ7+ [0] ---- 0.000 0.296 1.688 1.666 11.514
10 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.699 1.673 11.621
11 - 202224****** IQ7+M [0] ---- 0.000 0.296 1.733 1.697 11.838
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.283 1.833 1.675 12.450 0.000 kW
1.882 kWh
0.000 kW
7.529 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.285 1.852 1.716 12.680
14 - 202216****** IQ7+ [0] ---- 0.000 0.297 1.925 1.784 13.230
15 - 202245****** IQ7+M [0] ---- 0.000 0.285 1.919 1.783 13.211
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.20 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 518.7 Ah (26.6 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 87.5 % State Of Health 98.9 %
Run Time 14d 9h 48m to empty Report Date 2024-06-27 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack