Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.603 kW
03/10/2026 11:08 (2113 days) Production Consumption NET Usage
Now 2.664 kW 0.061 kW -2.603 kW
Today 4.068 kWh (0.365 kW) 4.872 kWh (0.437 kW) 0.804 kWh (0.072 kW)
  - This Week 40.249 kWh (16.331 kWh/day) 32.546 kWh (13.206 kWh/day) -7.703 kWh (-3.126 kWh/day)
  - This Month 133.957 kWh (14.154 kWh/day) 138.845 kWh (14.670 kWh/day) 4.888 kWh (0.516 kWh/day)
  - This Year 0.768 MWh (11.216 kWh/day) 1.239 MWh (18.092 kWh/day) 0.471 MWh (6.877 kWh/day)
Yesterday 25.455 kWh (1.061 kW) 15.204 kWh (0.633 kW) -10.251 kWh (-0.427 kW)
Last 7 Days 79.914 kWh (11.416 kWh/day) 105.035 kWh (15.005 kWh/day) 25.121 kWh (3.589 kWh/day)
Last 30 Days 401.368 kWh (13.379 kWh/day) 500.185 kWh (16.673 kWh/day) 98.817 kWh (3.294 kWh/day)
Last One Year 6.062 MWh (16.608 kWh/day) 7.800 MWh (21.369 kWh/day) 1.738 MWh (4.760 kWh/day)
Lifetime Since PTO 36.334 MWh (17.191 kW/day) 40.749 MWh (19.281 kW/day) 4.416 MWh (2.089 kW/day)
Lifetime Since Install 36.367 MWh 41.329 MWh 4.962 MWh
Voltage/Current 250.2 V / 10.6 A 250.2 V / 0.2 A 250.2 V / -10.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/12/2024 23:54 (23.9 hours) Number of Devices 17 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 27.089 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.517 1.486 8.156 0.000 kW
1.437 kWh
0.000 kW
8.622 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.292 1.412 1.398 7.625
03 - 202224****** IQ7+M [5] VCOP 0.000 0.293 1.475 1.454 7.939
04 - 202232****** IQ7+ [5] VCOP 0.000 0.293 1.508 1.475 8.079
05 - 202244****** IQ7+M [5] VCOP 0.000 0.289 1.292 1.324 7.191
06 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.418 1.405 7.727
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.290 1.386 1.429 7.479 0.000 kW
1.402 kWh
0.000 kW
7.009 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.291 1.390 1.426 7.498
09 - 202217****** IQ7+ [5] VCOP 0.000 0.293 1.389 1.422 7.462
10 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.400 1.441 7.523
11 - 202224****** IQ7+M [5] VCOP 0.000 0.292 1.444 1.467 7.645
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.273 1.448 1.290 7.403 0.000 kW
1.490 kWh
0.000 kW
5.961 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.284 1.445 1.297 7.572
14 - 202216****** IQ7+ [5] VCOP 0.000 0.273 1.538 1.389 7.933
15 - 202245****** IQ7+M [5] VCOP 0.000 0.276 1.530 1.383 7.912
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.749 kWh
0.230 kW
5.497 kWh
17 - 122214****** IQ7PD [5] VCOP 0.230 0.230 5.497 5.480 16.935
Panel Layout Each Group Production

Battery History
Voltage 53.12 V Current/Power -6.21 A (-0.330 kW)
Remain Capacity/Energy 411.3 Ah (21.1 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 69.4 % State Of Health 98.9 %
Run Time 2d 18h 14m to empty Report Date 2024-08-12 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.