Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.337 kW
03/10/2026 13:26 (2113 days) Production Consumption NET Usage
Now 3.566 kW 0.229 kW -3.337 kW
Today 11.558 kWh (0.859 kW) 7.555 kWh (0.562 kW) -4.003 kWh (-0.298 kW)
  - This Week 47.739 kWh (18.644 kWh/day) 35.229 kWh (13.759 kWh/day) -12.510 kWh (-4.886 kWh/day)
  - This Month 141.447 kWh (14.795 kWh/day) 141.528 kWh (14.804 kWh/day) 0.081 kWh (0.008 kWh/day)
  - This Year 0.775 MWh (11.309 kWh/day) 1.241 MWh (18.106 kWh/day) 0.466 MWh (6.797 kWh/day)
Yesterday 25.455 kWh (1.061 kW) 15.204 kWh (0.633 kW) -10.251 kWh (-0.427 kW)
Last 7 Days 85.793 kWh (12.256 kWh/day) 106.094 kWh (15.156 kWh/day) 20.301 kWh (2.900 kWh/day)
Last 30 Days 394.608 kWh (13.154 kWh/day) 498.302 kWh (16.610 kWh/day) 103.694 kWh (3.456 kWh/day)
Last One Year 6.054 MWh (16.586 kWh/day) 7.798 MWh (21.365 kWh/day) 1.744 MWh (4.778 kWh/day)
Lifetime Since PTO 36.341 MWh (17.194 kW/day) 40.752 MWh (19.281 kW/day) 4.411 MWh (2.087 kW/day)
Lifetime Since Install 36.375 MWh 41.332 MWh 4.957 MWh
Voltage/Current 251.5 V / 14.2 A 251.3 V / 0.9 A 251.4 V / -13.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/28/2024 23:27 (14.0 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 24.316 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.283 1.710 2.051 9.865 0.000 kW
1.628 kWh
0.000 kW
9.766 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.263 1.601 1.936 9.273
03 - 202224****** IQ7+M [5] VCOP 0.000 0.273 1.653 1.997 9.579
04 - 202232****** IQ7+ [5] VCOP 0.000 0.287 1.688 2.030 9.721
05 - 202244****** IQ7+M [5] VCOP 0.000 0.262 1.482 1.799 8.708
06 - 202245****** IQ7+M [5] VCOP 0.000 0.272 1.633 1.967 9.451
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.270 1.526 1.924 9.007 0.000 kW
1.536 kWh
0.000 kW
7.681 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.278 1.547 1.891 8.950
09 - 202217****** IQ7+ [5] VCOP 0.000 0.267 1.532 1.891 8.943
10 - 202244****** IQ7+M [5] VCOP 0.000 0.271 1.527 1.911 9.008
11 - 202224****** IQ7+M [5] VCOP 0.000 0.278 1.549 1.948 9.138
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.235 1.650 1.899 9.159 0.000 kW
1.717 kWh
0.000 kW
6.869 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.244 1.697 1.919 9.425
14 - 202216****** IQ7+ [5] VCOP 0.000 0.246 1.759 2.012 9.819
15 - 202245****** IQ7+M [5] VCOP 0.000 0.247 1.762 2.017 9.818
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 52.62 V Current/Power -2.10 A (-0.110 kW)
Remain Capacity/Energy 267.3 Ah (13.7 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 45.1 % State Of Health 98.9 %
Run Time 5d 7h 17m to empty Report Date 2024-07-28 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.58 V Cell (MIN/MAX) 3.281 V / 3.291 V (0.010 V)
Current/Power -0.70 A (-36 W) Runtime 5d 7h 6m to empty
Remain Capacity/Energy 89.1 Ah (4.6 kWh) Full Capacity/Energy 197.7 Ah (10.1 kWh)
State Of Charge 45.1 % State Of Health 98.8 %
Temperature 26.5 °C Cycle 160
MOSFET CFET = ON, DFET = ON Reported 2024-07-28 23:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.281 V 3.282 V 3.282 V 3.283 V 3.284 V 3.284 V 3.285 V 3.285 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.286 V 3.287 V 3.287 V 3.288 V 3.289 V 3.289 V 3.291 V 3.290 V
pack voltage and current cell voltages
pack temperature
Voltage 52.61 V Cell (MIN/MAX) 3.287 V / 3.289 V (0.002 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 47.9 Ah (2.5 kWh) Full Capacity/Energy 99.5 Ah (5.1 kWh)
State Of Charge 48.2 % State Of Health 99.5 %
Temperature 26.8 °C Cycle 98
MOSFET CFET = ON, DFET = ON Reported 2024-07-28 23:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.287 V 3.287 V 3.289 V 3.287 V 3.289 V 3.289 V 3.287 V 3.289 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.287 V 3.287 V 3.287 V 3.287 V 3.289 V 3.288 V 3.287 V 3.287 V
pack voltage and current cell voltages
pack temperature
JpGraph Error: 25107 Can't write to file "images/chart_batt2_2.png". Check that the process running PHP has enough permission.