Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.113 kW
05/15/2026 02:47 (2179 days) Production Consumption NET Usage
Now 0.000 kW 0.113 kW 0.113 kW
Today 0.000 kWh (0.000 kW) 0.804 kWh (0.287 kW) 0.804 kWh (0.287 kW)
  - This Week 129.528 kWh (25.312 kWh/day) 66.956 kWh (13.084 kWh/day) -62.572 kWh (-12.228 kWh/day)
  - This Month 347.603 kWh (24.623 kWh/day) 184.093 kWh (13.041 kWh/day) -163.510 kWh (-11.583 kWh/day)
  - This Year 2.301 MWh (17.154 kWh/day) 2.244 MWh (16.730 kWh/day) -0.057 MWh (-0.424 kWh/day)
Yesterday 22.227 kWh (0.926 kW) 14.790 kWh (0.616 kW) -7.437 kWh (-0.310 kW)
Last 7 Days 160.378 kWh (22.911 kWh/day) 135.330 kWh (19.333 kWh/day) -25.048 kWh (-3.578 kWh/day)
Last 30 Days (04/15/2026) 693.955 kWh (23.132 kWh/day) 416.838 kWh (13.895 kWh/day) -277.117 kWh (-9.237 kWh/day)
Last One Year 6.329 MWh (17.341 kWh/day) 7.793 MWh (21.351 kWh/day) 1.464 MWh (4.010 kWh/day)
Lifetime Since PTO 37.866 MWh (17.377 kW/day) 41.755 MWh (19.161 kW/day) 3.888 MWh (1.784 kW/day)
Lifetime Since Install 37.900 MWh 42.335 MWh 4.434 MWh
Voltage/Current 251.4 V / 0.0 A 251.3 V / 0.4 A 251.3 V / 0.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/17/2024 23:07 (11.7 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 17.638 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.265 1.253 1.684 12.241 0.000 kW
1.223 kWh
0.000 kW
7.339 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.255 1.194 1.613 11.686
03 - 202224****** IQ7+M [0] ---- 0.000 0.262 1.238 1.675 12.160
04 - 202232****** IQ7+ [0] ---- 0.000 0.267 1.249 1.693 12.301
05 - 202244****** IQ7+M [0] ---- 0.000 0.253 1.188 1.559 11.369
06 - 202245****** IQ7+M [0] ---- 0.000 0.259 1.217 1.590 11.608
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.288 1.315 1.626 12.078 0.000 kW
1.318 kWh
0.000 kW
6.589 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.293 1.323 1.752 12.808
09 - 202217****** IQ7+ [0] ---- 0.000 0.278 1.312 1.744 12.610
10 - 202244****** IQ7+M [0] ---- 0.000 0.269 1.309 1.740 12.725
11 - 202224****** IQ7+M [0] ---- 0.000 0.290 1.330 1.768 12.953
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.211 0.879 1.280 9.082 0.000 kW
0.928 kWh
0.000 kW
3.710 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.217 0.916 1.323 9.300
14 - 202216****** IQ7+ [0] ---- 0.000 0.223 0.960 1.383 9.763
15 - 202245****** IQ7+M [0] ---- 0.000 0.222 0.955 1.377 9.707
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 1.222
Panel Layout Each Group Production

Charger History
Voltage PV 2.03 V Voltage Charge 52.97 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 29.3 °C / 27.3 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2024-09-17 23:59
voltage in/out power and energy internal/external temperature

Battery History
Voltage 53.19 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 517.5 Ah (26.5 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 87.3 % State Of Health 98.9 %
Run Time 14d 9h 0m to empty Report Date 2024-09-17 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.