Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.053 kW
09/11/2025 07:16 (1933 days) Production Consumption NET Usage
Now 0.204 kW 0.151 kW -0.053 kW
Today 0.043 kWh (0.006 kW) 2.742 kWh (0.376 kW) 2.699 kWh (0.371 kW)
  - This Week 79.134 kWh (18.388 kWh/day) 56.297 kWh (13.081 kWh/day) -22.837 kWh (-5.306 kWh/day)
  - This Month 216.062 kWh (20.970 kWh/day) 252.022 kWh (24.460 kWh/day) 35.960 kWh (3.490 kWh/day)
  - This Year 4.723 MWh (18.647 kWh/day) 5.423 MWh (21.408 kWh/day) 0.699 MWh (2.761 kWh/day)
Yesterday 13.894 kWh (0.579 kW) 11.180 kWh (0.466 kW) -2.714 kWh (-0.113 kW)
Last 7 Days 139.967 kWh (19.995 kWh/day) 161.355 kWh (23.051 kWh/day) 21.388 kWh (3.055 kWh/day)
Last 30 Days 686.595 kWh (22.886 kWh/day) 790.536 kWh (26.350 kWh/day) 103.941 kWh (3.465 kWh/day)
Last One Year 6.279 MWh (17.202 kWh/day) 7.074 MWh (19.380 kWh/day) 0.795 MWh (2.177 kWh/day)
Lifetime Since PTO 34.174 MWh (17.677 kW/day) 37.375 MWh (19.332 kW/day) 3.200 MWh (1.655 kW/day)
Lifetime Since Install 34.208 MWh 37.955 MWh 3.747 MWh
Voltage/Current 252.9 V / 0.8 A 252.9 V / 0.6 A 252.9 V / -0.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/08/2024 23:05 (8.8 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 9.584 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.205 0.512 0.030 3.943 0.000 kW
0.501 kWh
0.000 kW
3.007 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.188 0.435 0.026 3.753
03 - 202224****** IQ7+M [5] VCOP 0.000 0.190 0.423 0.028 3.943
04 - 202232****** IQ7+ [5] VCOP 0.000 0.189 0.452 0.027 3.960
05 - 202244****** IQ7+M [5] VCOP 0.000 0.202 0.570 0.026 3.769
06 - 202245****** IQ7+M [5] VCOP 0.000 0.204 0.615 0.027 3.795
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.273 0.979 0.048 4.115 0.000 kW
1.173 kWh
0.000 kW
5.864 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.271 1.124 0.050 4.652
09 - 202217****** IQ7+ [5] VCOP 0.000 0.273 1.299 0.244 5.068
10 - 202244****** IQ7+M [5] VCOP 0.000 0.271 1.273 0.287 5.026
11 - 202224****** IQ7+M [5] VCOP 0.000 0.276 1.188 0.285 4.852
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.061 0.221 0.032 1.689 0.000 kW
0.178 kWh
0.000 kW
0.714 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.048 0.168 0.030 1.971
14 - 202216****** IQ7+ [5] VCOP 0.000 0.035 0.152 0.033 2.075
15 - 202245****** IQ7+M [5] VCOP 0.000 0.048 0.173 0.034 2.042
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 15.465 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.