Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.659 kW
07/02/2026 11:46 (2227 days) Production Consumption NET Usage
Now 3.634 kW 2.975 kW -0.659 kW
Today 11.548 kWh (0.979 kW) 13.592 kWh (1.152 kW) 2.044 kWh (0.173 kW)
  - This Week 118.780 kWh (26.451 kWh/day) 129.883 kWh (28.924 kWh/day) 11.103 kWh (2.473 kWh/day)
  - This Month 37.179 kWh (24.933 kWh/day) 55.743 kWh (37.382 kWh/day) 18.564 kWh (12.449 kWh/day)
  - This Year 3.647 MWh (19.985 kWh/day) 3.343 MWh (18.316 kWh/day) -0.304 MWh (-1.669 kWh/day)
Yesterday 25.631 kWh (1.069 kW) 42.151 kWh (1.757 kW) 16.520 kWh (0.689 kW)
Last 7 Days 166.503 kWh (23.786 kWh/day) 179.319 kWh (25.617 kWh/day) 12.816 kWh (1.831 kWh/day)
Last 30 Days (06/02/2026) 862.534 kWh (28.751 kWh/day) 757.024 kWh (25.234 kWh/day) -105.510 kWh (-3.517 kWh/day)
Last One Year 6.706 MWh (18.371 kWh/day) 7.734 MWh (21.188 kWh/day) 1.028 MWh (2.817 kWh/day)
Lifetime Since PTO 39.213 MWh (17.604 kW/day) 42.853 MWh (19.238 kW/day) 3.641 MWh (1.634 kW/day)
Lifetime Since Install 39.247 MWh 43.433 MWh 4.187 MWh
Voltage/Current 248.0 V / 14.7 A 248.0 V / 12.0 A 248.0 V / -2.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/27/2024 23:58 (16.4 hours) Number of Devices 18 set
Current Power 0.230 kW (0.013 kW/panel) Today Energy 21.944 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.242 1.411 1.288 9.103 0.000 kW
1.353 kWh
0.000 kW
8.115 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.230 1.323 1.227 8.675
03 - 202224****** IQ7+M [5] VCOP 0.000 0.235 1.348 1.256 8.925
04 - 202232****** IQ7+ [5] VCOP 0.000 0.237 1.334 1.245 8.920
05 - 202244****** IQ7+M [5] VCOP 0.000 0.229 1.333 1.237 8.711
06 - 202245****** IQ7+M [5] VCOP 0.000 0.234 1.367 1.255 8.843
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.284 1.428 1.327 9.455 0.000 kW
1.600 kWh
0.000 kW
8.002 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.286 1.586 1.477 10.407
09 - 202217****** IQ7+ [5] VCOP 0.000 0.284 1.680 1.558 11.074
10 - 202244****** IQ7+M [5] VCOP 0.000 0.281 1.662 1.542 10.889
11 - 202224****** IQ7+M [5] VCOP 0.000 0.287 1.646 1.533 10.807
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.128 0.660 0.631 4.711 0.000 kW
0.741 kWh
0.000 kW
2.964 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.134 0.751 0.712 5.278
14 - 202216****** IQ7+ [5] VCOP 0.000 0.137 0.782 0.741 5.508
15 - 202245****** IQ7+M [5] VCOP 0.000 0.136 0.771 0.732 5.443
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.077 kW
0.954 kWh
0.230 kW
2.862 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.230 0.230 2.862 0.744 0.744
Panel Layout Each Group Production

Charger History
Voltage PV 0.48 V Voltage Charge 52.86 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 27.8 °C / 25.4 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2024-10-27 23:55
voltage in/out power and energy internal/external temperature
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.