Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.413 kW
03/10/2026 13:27 (2113 days) Production Consumption NET Usage
Now 3.566 kW 0.153 kW -3.413 kW
Today 11.590 kWh (0.861 kW) 7.557 kWh (0.562 kW) -4.033 kWh (-0.300 kW)
  - This Week 47.771 kWh (18.654 kWh/day) 35.231 kWh (13.757 kWh/day) -12.540 kWh (-4.897 kWh/day)
  - This Month 141.479 kWh (14.798 kWh/day) 141.530 kWh (14.803 kWh/day) 0.051 kWh (0.005 kWh/day)
  - This Year 0.775 MWh (11.310 kWh/day) 1.241 MWh (18.106 kWh/day) 0.466 MWh (6.796 kWh/day)
Yesterday 25.455 kWh (1.061 kW) 15.204 kWh (0.633 kW) -10.251 kWh (-0.427 kW)
Last 7 Days 85.818 kWh (12.260 kWh/day) 106.094 kWh (15.156 kWh/day) 20.276 kWh (2.897 kWh/day)
Last 30 Days 394.579 kWh (13.153 kWh/day) 498.300 kWh (16.610 kWh/day) 103.721 kWh (3.457 kWh/day)
Last One Year 6.054 MWh (16.586 kWh/day) 7.798 MWh (21.365 kWh/day) 1.744 MWh (4.778 kWh/day)
Lifetime Since PTO 36.341 MWh (17.194 kW/day) 40.752 MWh (19.281 kW/day) 4.411 MWh (2.087 kW/day)
Lifetime Since Install 36.375 MWh 41.332 MWh 4.957 MWh
Voltage/Current 251.2 V / 14.2 A 251.3 V / 0.6 A 251.3 V / -13.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/29/2024 23:28 (14.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 17.594 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.225 2.350 13.417 0.000 kW
1.199 kWh
0.000 kW
7.194 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.175 2.179 12.550
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.217 2.208 12.728
04 - 202232****** IQ7+ [5] VCOP 0.000 0.297 1.225 2.265 12.953
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.165 1.954 11.312
06 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.188 2.250 12.896
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.149 2.133 11.970 0.000 kW
1.156 kWh
0.000 kW
5.780 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.153 2.041 11.692
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.154 2.066 11.804
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.155 2.105 11.920
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.169 2.144 12.132
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.292 1.097 2.261 12.797 0.000 kW
1.155 kWh
0.000 kW
4.619 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.296 1.142 2.258 12.991
14 - 202216****** IQ7+ [5] VCOP 0.000 0.296 1.190 2.392 13.578
15 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.190 2.391 13.552
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 52.60 V Current/Power -2.01 A (-0.106 kW)
Remain Capacity/Energy 251.1 Ah (12.9 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 42.3 % State Of Health 98.9 %
Run Time 5d 4h 55m to empty Report Date 2024-06-29 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.