Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.584 kW
07/01/2026 11:33 (2226 days) Production Consumption NET Usage
Now 3.297 kW 2.713 kW -0.584 kW
Today 8.153 kWh (0.704 kW) 10.035 kWh (0.867 kW) 1.882 kWh (0.163 kW)
  - This Week 89.754 kWh (25.779 kWh/day) 84.175 kWh (24.176 kWh/day) -5.579 kWh (-1.602 kWh/day)
  - This Month 8.153 kWh (16.904 kWh/day) 10.035 kWh (20.806 kWh/day) 1.882 kWh (3.902 kWh/day)
  - This Year 3.618 MWh (19.936 kWh/day) 3.297 MWh (18.166 kWh/day) -0.321 MWh (-1.770 kWh/day)
Yesterday 26.873 kWh (1.121 kW) 21.329 kWh (0.889 kW) -5.544 kWh (-0.231 kW)
Last 7 Days 170.036 kWh (24.291 kWh/day) 158.276 kWh (22.611 kWh/day) -11.760 kWh (-1.680 kWh/day)
Last 30 Days (06/01/2026) 872.782 kWh (29.093 kWh/day) 721.782 kWh (24.059 kWh/day) -151.000 kWh (-5.033 kWh/day)
Last One Year 6.696 MWh (18.346 kWh/day) 7.719 MWh (21.147 kWh/day) 1.022 MWh (2.800 kWh/day)
Lifetime Since PTO 39.184 MWh (17.599 kW/day) 42.808 MWh (19.227 kW/day) 3.624 MWh (1.628 kW/day)
Lifetime Since Install 39.218 MWh 43.388 MWh 4.170 MWh
Voltage/Current 246.7 V / 13.4 A 246.8 V / 11.0 A 246.7 V / -2.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 04/30/2026 23:57 (23.9 hours) Number of Devices 18 set
Current Power 0.321 kW (0.018 kW/panel) Today Energy 17.329 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.225 0.667 1.439 10.765 0.000 kW
0.647 kWh
0.000 kW
3.881 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.183 0.634 1.353 10.150
03 - 202224****** IQ7+M [5] VCOP 0.000 0.199 0.663 1.418 10.617
04 - 202232****** IQ7+ [5] VCOP 0.000 0.199 0.645 1.439 10.734
05 - 202244****** IQ7+M [5] VCOP 0.000 0.192 0.622 1.247 9.594
06 - 202245****** IQ7+M [5] VCOP 0.000 0.195 0.649 1.367 10.261
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.207 0.615 1.270 9.975 0.000 kW
0.611 kWh
0.000 kW
3.053 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.216 0.597 1.321 10.093
09 - 202217****** IQ7+ [5] VCOP 0.000 0.218 0.601 1.324 10.071
10 - 202244****** IQ7+M [5] VCOP 0.000 0.202 0.608 1.321 10.206
11 - 202224****** IQ7+M [5] VCOP 0.000 0.216 0.632 1.333 10.384
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.183 0.588 1.465 10.099 0.000 kW
0.621 kWh
0.000 kW
2.483 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.179 0.611 1.506 10.178
14 - 202216****** IQ7+ [5] VCOP 0.000 0.206 0.639 1.538 10.551
15 - 202245****** IQ7+M [5] VCOP 0.000 0.191 0.645 1.555 10.597
wind 16 - 202320****** IQ7XS [0] ---- 0.321 0.322 7.696 7.678 42.676 0.107 kW
2.637 kWh
0.321 kW
7.912 kWh
17 - 122344****** IQ7AS [4] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [0] ---- 0.000 0.100 0.216 0.640 4.765
Panel Layout Each Group Production

Charger History
Voltage PV 1.21 V Voltage Charge 52.06 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 28.1 °C / 25.8 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2026-04-30 23:57
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.33 V Current/Power -7.90 A (-0.413 kW)
Remain Capacity/Energy 193.0 Ah (9.9 kWh) Full Capacity/Energy 548.1 Ah (28.1 kWh)
State Of Charge 35.2 % State Of Health 91.4 %
Run Time 1d 0h 26m to empty Report Date 2026-04-30 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.