Exporting to grid by 1.225 kW
07/02/2026 14:21 (2227 days) Production Consumption NET Usage
Now 3.983 kW 2.758 kW -1.225 kW
Today 21.500 kWh (1.495 kW) 20.158 kWh (1.402 kW) -1.342 kWh (-0.093 kW)
  - This Week 128.732 kWh (27.996 kWh/day) 136.449 kWh (29.675 kWh/day) 7.717 kWh (1.678 kWh/day)
  - This Month 47.131 kWh (29.480 kWh/day) 62.309 kWh (38.974 kWh/day) 15.178 kWh (9.494 kWh/day)
  - This Year 3.657 MWh (20.027 kWh/day) 3.349 MWh (18.341 kWh/day) -0.308 MWh (-1.686 kWh/day)
Yesterday 25.631 kWh (1.069 kW) 42.151 kWh (1.757 kW) 16.520 kWh (0.689 kW)
Last 7 Days 166.673 kWh (23.810 kWh/day) 184.182 kWh (26.312 kWh/day) 17.509 kWh (2.501 kWh/day)
Last 30 Days (06/02/2026) 861.922 kWh (28.731 kWh/day) 760.858 kWh (25.362 kWh/day) -101.064 kWh (-3.369 kWh/day)
Last One Year 6.710 MWh (18.383 kWh/day) 7.739 MWh (21.203 kWh/day) 1.029 MWh (2.819 kWh/day)
Lifetime Since PTO 39.223 MWh (17.608 kW/day) 42.860 MWh (19.240 kW/day) 3.637 MWh (1.633 kW/day)
Lifetime Since Install 39.257 MWh 43.440 MWh 4.183 MWh
Voltage/Current 247.5 V / 16.1 A 247.4 V / 11.1 A 247.5 V / -4.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/23/2024 23:44 (11.7 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 9.580 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.165 0.674 1.676 9.811 0.000 kW
0.651 kWh
0.000 kW
3.907 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.167 0.636 1.604 9.366
03 - 202224****** IQ7+M [5] VCOP 0.000 0.173 0.665 1.662 9.713
04 - 202232****** IQ7+ [5] VCOP 0.000 0.170 0.668 1.679 9.816
05 - 202244****** IQ7+M [5] VCOP 0.000 0.165 0.619 1.561 9.151
06 - 202245****** IQ7+M [5] VCOP 0.000 0.169 0.647 1.588 9.354
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.144 0.592 1.593 9.679 0.000 kW
0.608 kWh
0.000 kW
3.041 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.161 0.613 1.756 10.226
09 - 202217****** IQ7+ [5] VCOP 0.000 0.164 0.610 1.755 10.170
10 - 202244****** IQ7+M [5] VCOP 0.000 0.155 0.610 1.743 10.158
11 - 202224****** IQ7+M [5] VCOP 0.000 0.166 0.615 1.778 10.317
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.154 0.615 1.217 7.169 0.000 kW
0.658 kWh
0.000 kW
2.631 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.158 0.651 1.261 7.442
14 - 202216****** IQ7+ [5] VCOP 0.000 0.164 0.682 1.316 7.815
15 - 202245****** IQ7+M [5] VCOP 0.000 0.160 0.684 1.310 7.777
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Charger History
Voltage PV 1.54 V Voltage Charge 52.97 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 28.3 °C / 27.0 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2024-09-23 23:59
voltage in/out power and energy internal/external temperature

Battery History
Voltage 53.19 V Current/Power -1.62 A (-86 W)
Remain Capacity/Energy 516.3 Ah (26.4 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 87.1 % State Of Health 98.9 %
Run Time 13d 6h 42m to empty Report Date 2024-09-23 23:57