Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.419 kW
03/10/2026 16:04 (2113 days) Production Consumption NET Usage
Now 2.705 kW 0.286 kW -2.419 kW
Today 20.016 kWh (1.245 kW) 9.196 kWh (0.572 kW) -10.820 kWh (-0.673 kW)
  - This Week 56.197 kWh (21.049 kWh/day) 36.870 kWh (13.810 kWh/day) -19.327 kWh (-7.239 kWh/day)
  - This Month 149.905 kWh (15.503 kWh/day) 143.169 kWh (14.806 kWh/day) -6.736 kWh (-0.697 kWh/day)
  - This Year 0.784 MWh (11.414 kWh/day) 1.243 MWh (18.101 kWh/day) 0.459 MWh (6.687 kWh/day)
Yesterday 25.455 kWh (1.061 kW) 15.204 kWh (0.633 kW) -10.251 kWh (-0.427 kW)
Last 7 Days 92.685 kWh (13.241 kWh/day) 106.615 kWh (15.231 kWh/day) 13.930 kWh (1.990 kWh/day)
Last 30 Days 386.192 kWh (12.873 kWh/day) 496.701 kWh (16.557 kWh/day) 110.509 kWh (3.684 kWh/day)
Last One Year 6.045 MWh (16.561 kWh/day) 7.797 MWh (21.361 kWh/day) 1.752 MWh (4.800 kWh/day)
Lifetime Since PTO 36.350 MWh (17.197 kW/day) 40.754 MWh (19.281 kW/day) 4.404 MWh (2.084 kW/day)
Lifetime Since Install 36.383 MWh 41.334 MWh 4.950 MWh
Voltage/Current 250.1 V / 10.8 A 250.2 V / 1.1 A 250.2 V / -9.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/30/2024 23:57 (13.2 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 16.574 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.277 1.178 1.652 13.372 0.000 kW
1.147 kWh
0.000 kW
6.881 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.264 1.121 1.550 12.673
03 - 202224****** IQ7+M [5] VCOP 0.000 0.273 1.167 1.611 13.174
04 - 202232****** IQ7+ [5] VCOP 0.000 0.276 1.168 1.650 13.407
05 - 202244****** IQ7+M [5] VCOP 0.000 0.261 1.106 1.442 12.030
06 - 202245****** IQ7+M [5] VCOP 0.000 0.269 1.141 1.561 12.746
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.293 1.184 1.515 12.725 0.000 kW
1.175 kWh
0.000 kW
5.875 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.293 1.165 1.536 12.607
09 - 202217****** IQ7+ [5] VCOP 0.000 0.289 1.158 1.524 12.523
10 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.172 1.528 12.750
11 - 202224****** IQ7+M [5] VCOP 0.000 0.293 1.196 1.557 13.039
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.196 0.910 1.559 11.725 0.000 kW
0.955 kWh
0.000 kW
3.818 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.197 0.912 1.596 11.889
14 - 202216****** IQ7+ [5] VCOP 0.000 0.213 1.001 1.659 12.477
15 - 202245****** IQ7+M [5] VCOP 0.000 0.208 0.995 1.656 12.454
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.415
Panel Layout Each Group Production

Battery History
Voltage 53.30 V Current/Power -1.83 A (-97 W)
Remain Capacity/Energy 441.3 Ah (22.6 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 74.4 % State Of Health 98.9 %
Run Time 10d 1h 8m to empty Report Date 2024-04-30 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.30 V Cell (MIN/MAX) 3.325 V / 3.335 V (0.010 V)
Current/Power -0.59 A (-31 W) Runtime 10d 8h 54m to empty
Remain Capacity/Energy 147.1 Ah (7.5 kWh) Full Capacity/Energy 197.7 Ah (10.1 kWh)
State Of Charge 74.4 % State Of Health 98.8 %
Temperature 20.5 °C Cycle 144
MOSFET CFET = ON, DFET = ON Reported 2024-04-30 23:57
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.325 V 3.327 V 3.326 V 3.328 V 3.328 V 3.329 V 3.330 V 3.330 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.331 V 3.332 V 3.332 V 3.334 V 3.334 V 3.335 V 3.335 V 3.335 V
pack voltage and current cell voltages
pack temperature
JpGraph Error: 25107 Can't write to file "images/chart_batt2_1.png". Check that the process running PHP has enough permission.