Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.246 kW
05/15/2026 06:02 (2179 days) Production Consumption NET Usage
Now 0.091 kW 0.337 kW 0.246 kW
Today 0.006 kWh (0.001 kW) 1.855 kWh (0.307 kW) 1.849 kWh (0.306 kW)
  - This Week 129.534 kWh (24.663 kWh/day) 68.007 kWh (12.948 kWh/day) -61.527 kWh (-11.714 kWh/day)
  - This Month 347.609 kWh (24.390 kWh/day) 185.144 kWh (12.991 kWh/day) -162.465 kWh (-11.400 kWh/day)
  - This Year 2.301 MWh (17.137 kWh/day) 2.245 MWh (16.721 kWh/day) -0.056 MWh (-0.416 kWh/day)
Yesterday 22.227 kWh (0.926 kW) 14.790 kWh (0.616 kW) -7.437 kWh (-0.310 kW)
Last 7 Days 160.382 kWh (22.912 kWh/day) 136.586 kWh (19.512 kWh/day) -23.796 kWh (-3.399 kWh/day)
Last 30 Days (04/15/2026) 692.927 kWh (23.098 kWh/day) 416.390 kWh (13.880 kWh/day) -276.537 kWh (-9.218 kWh/day)
Last One Year 6.329 MWh (17.341 kWh/day) 7.793 MWh (21.351 kWh/day) 1.464 MWh (4.010 kWh/day)
Lifetime Since PTO 37.866 MWh (17.376 kW/day) 41.756 MWh (19.161 kW/day) 3.889 MWh (1.785 kW/day)
Lifetime Since Install 37.900 MWh 42.336 MWh 4.435 MWh
Voltage/Current 250.0 V / 0.4 A 250.2 V / 1.3 A 250.1 V / 1.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/05/2024 23:56 (23.9 hours) Number of Devices 17 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 26.489 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.282 1.477 1.678 13.187 0.000 kW
1.442 kWh
0.000 kW
8.651 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.293 1.415 1.596 12.363
03 - 202224****** IQ7+M [5] VC-- 0.000 0.295 1.468 1.657 12.612
04 - 202232****** IQ7+ [5] VCOP 0.000 0.286 1.469 1.674 12.878
05 - 202244****** IQ7+M [5] VCOP 0.000 0.293 1.391 1.526 11.312
06 - 202245****** IQ7+M [5] VCOP 0.000 0.292 1.432 1.623 12.699
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.294 1.428 1.568 11.940 0.000 kW
1.429 kWh
0.000 kW
7.144 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.294 1.415 1.553 11.621
09 - 202217****** IQ7+ [5] VCOP 0.000 0.293 1.429 1.549 11.701
10 - 202244****** IQ7+M [5] VCOP 0.000 0.293 1.428 1.564 11.884
11 - 202224****** IQ7+M [5] VCOP 0.000 0.293 1.444 1.586 12.115
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.273 1.235 1.475 12.429 0.000 kW
1.298 kWh
0.000 kW
5.192 kWh
13 - 202223****** IQ7+ [5] VC-- 0.000 0.278 1.271 1.521 12.598
14 - 202216****** IQ7+ [5] VCOP 0.000 0.282 1.342 1.579 13.226
15 - 202245****** IQ7+M [5] VCOP 0.000 0.283 1.344 1.588 13.220
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.751 kWh
0.230 kW
5.502 kWh
17 - 122214****** IQ7PD [5] VC-- 0.230 0.230 5.502 5.478 21.928
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.