Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.251 kW
07/02/2026 14:23 (2227 days) Production Consumption NET Usage
Now 4.021 kW 2.770 kW -1.251 kW
Today 21.645 kWh (1.501 kW) 20.259 kWh (1.405 kW) -1.386 kWh (-0.096 kW)
  - This Week 128.877 kWh (28.019 kWh/day) 136.550 kWh (29.687 kWh/day) 7.673 kWh (1.668 kWh/day)
  - This Month 47.276 kWh (29.543 kWh/day) 62.410 kWh (39.000 kWh/day) 15.134 kWh (9.457 kWh/day)
  - This Year 3.657 MWh (20.028 kWh/day) 3.349 MWh (18.342 kWh/day) -0.308 MWh (-1.686 kWh/day)
Yesterday 25.631 kWh (1.069 kW) 42.151 kWh (1.757 kW) 16.520 kWh (0.689 kW)
Last 7 Days 166.784 kWh (23.826 kWh/day) 184.187 kWh (26.312 kWh/day) 17.403 kWh (2.486 kWh/day)
Last 30 Days (06/02/2026) 861.988 kWh (28.733 kWh/day) 760.950 kWh (25.365 kWh/day) -101.038 kWh (-3.368 kWh/day)
Last One Year 6.710 MWh (18.384 kWh/day) 7.739 MWh (21.203 kWh/day) 1.029 MWh (2.819 kWh/day)
Lifetime Since PTO 39.223 MWh (17.608 kW/day) 42.860 MWh (19.240 kW/day) 3.637 MWh (1.633 kW/day)
Lifetime Since Install 39.257 MWh 43.440 MWh 4.183 MWh
Voltage/Current 247.5 V / 16.2 A 247.4 V / 11.2 A 247.4 V / -5.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/08/2024 23:48 (12.8 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 3.451 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.073 0.244 0.310 8.614 0.000 kW
0.235 kWh
0.000 kW
1.410 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.068 0.228 0.290 8.015
03 - 202224****** IQ7+M [5] VCOP 0.000 0.071 0.243 0.308 8.331
04 - 202232****** IQ7+ [5] VCOP 0.000 0.072 0.241 0.306 8.503
05 - 202244****** IQ7+M [5] VCOP 0.000 0.067 0.222 0.283 7.439
06 - 202245****** IQ7+M [5] VCOP 0.000 0.068 0.231 0.293 8.173
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.065 0.217 0.274 7.691 0.000 kW
0.219 kWh
0.000 kW
1.093 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.063 0.218 0.277 7.717
09 - 202217****** IQ7+ [5] VCOP 0.000 0.063 0.219 0.276 7.680
10 - 202244****** IQ7+M [5] VCOP 0.000 0.064 0.218 0.277 7.737
11 - 202224****** IQ7+M [5] VCOP 0.000 0.065 0.220 0.279 7.861
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.064 0.217 0.278 8.179 0.000 kW
0.237 kWh
0.000 kW
0.948 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.069 0.231 0.298 8.419
14 - 202216****** IQ7+ [5] VCOP 0.000 0.071 0.252 0.318 8.737
15 - 202245****** IQ7+M [5] VCOP 0.000 0.071 0.248 0.315 8.725
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 31.817
Panel Layout Each Group Production