Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.731 kW
09/11/2025 10:51 (1933 days) Production Consumption NET Usage
Now 3.022 kW 0.291 kW -2.731 kW
Today 4.867 kWh (0.448 kW) 3.990 kWh (0.367 kW) -0.877 kWh (-0.081 kW)
  - This Week 83.958 kWh (18.855 kWh/day) 57.545 kWh (12.923 kWh/day) -26.413 kWh (-5.932 kWh/day)
  - This Month 220.886 kWh (21.132 kWh/day) 253.270 kWh (24.231 kWh/day) 32.384 kWh (3.098 kWh/day)
  - This Year 4.728 MWh (18.655 kWh/day) 5.424 MWh (21.400 kWh/day) 0.696 MWh (2.745 kWh/day)
Yesterday 13.894 kWh (0.579 kW) 11.180 kWh (0.466 kW) -2.714 kWh (-0.113 kW)
Last 7 Days 139.967 kWh (19.995 kWh/day) 161.355 kWh (23.051 kWh/day) 21.388 kWh (3.055 kWh/day)
Last 30 Days 686.595 kWh (22.886 kWh/day) 790.536 kWh (26.350 kWh/day) 103.941 kWh (3.465 kWh/day)
Last One Year 6.279 MWh (17.202 kWh/day) 7.074 MWh (19.380 kWh/day) 0.795 MWh (2.177 kWh/day)
Lifetime Since PTO 34.179 MWh (17.678 kW/day) 37.376 MWh (19.331 kW/day) 3.197 MWh (1.653 kW/day)
Lifetime Since Install 34.213 MWh 37.956 MWh 3.743 MWh
Voltage/Current 251.8 V / 12.0 A 251.7 V / 1.2 A 251.7 V / -10.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/18/2023 23:23 (10.5 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 10.657 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.223 0.719 0.806 7.842 0.000 kW
0.698 kWh
0.000 kW
4.187 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.205 0.680 0.767 7.452
03 - 202224****** IQ7+M [5] VCOP 0.000 0.248 0.710 0.795 7.674
04 - 202232****** IQ7+ [5] VCOP 0.000 0.222 0.713 0.790 7.639
05 - 202244****** IQ7+M [5] VCOP 0.000 0.212 0.672 0.757 7.427
06 - 202245****** IQ7+M [5] VCOP 0.000 0.216 0.693 0.780 7.606
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.257 0.694 0.686 7.619 0.000 kW
0.708 kWh
0.000 kW
3.539 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.238 0.710 0.790 8.368
09 - 202217****** IQ7+ [5] VCOP 0.000 0.248 0.712 0.851 8.562
10 - 202244****** IQ7+M [5] VCOP 0.000 0.255 0.707 0.849 8.580
11 - 202224****** IQ7+M [5] VCOP 0.000 0.250 0.716 0.836 8.628
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.150 0.555 0.580 4.877 0.000 kW
0.592 kWh
0.000 kW
2.370 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.155 0.589 0.621 5.216
14 - 202216****** IQ7+ [5] VCOP 0.000 0.148 0.610 0.649 5.433
15 - 202245****** IQ7+M [5] VCOP 0.000 0.160 0.615 0.648 5.409
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.230 0.561 0.558 4.581 0.000 kW
0.561 kWh
0.000 kW
0.561 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.20 V Current/Power -1.62 A (-86 W)
Remain Capacity/Energy 515.1 Ah (26.4 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 86.8 % State Of Health 98.9 %
Run Time 13d 5h 57m to empty Report Date 2023-10-18 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.