Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.614 kW
07/02/2026 15:23 (2227 days) Production Consumption NET Usage
Now 3.598 kW 1.984 kW -1.614 kW
Today 25.391 kWh (1.645 kW) 22.581 kWh (1.463 kW) -2.810 kWh (-0.182 kW)
  - This Week 132.623 kWh (28.571 kWh/day) 138.872 kWh (29.918 kWh/day) 6.249 kWh (1.346 kWh/day)
  - This Month 51.022 kWh (31.065 kWh/day) 64.732 kWh (39.412 kWh/day) 13.710 kWh (8.347 kWh/day)
  - This Year 3.661 MWh (20.044 kWh/day) 3.352 MWh (18.350 kWh/day) -0.309 MWh (-1.694 kWh/day)
Yesterday 25.631 kWh (1.069 kW) 42.151 kWh (1.757 kW) 16.520 kWh (0.689 kW)
Last 7 Days 167.751 kWh (23.964 kWh/day) 185.140 kWh (26.449 kWh/day) 17.389 kWh (2.484 kWh/day)
Last 30 Days (06/02/2026) 862.180 kWh (28.739 kWh/day) 763.315 kWh (25.444 kWh/day) -98.865 kWh (-3.295 kWh/day)
Last One Year 6.712 MWh (18.389 kWh/day) 7.739 MWh (21.203 kWh/day) 1.027 MWh (2.815 kWh/day)
Lifetime Since PTO 39.227 MWh (17.609 kW/day) 42.862 MWh (19.241 kW/day) 3.636 MWh (1.632 kW/day)
Lifetime Since Install 39.260 MWh 43.442 MWh 4.182 MWh
Voltage/Current 247.9 V / 14.5 A 247.9 V / 8.0 A 247.9 V / -6.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/03/2024 23:57 (23.9 hours) Number of Devices 18 set
Current Power 0.230 kW (0.013 kW/panel) Today Energy 24.279 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.281 1.325 1.051 11.259 0.000 kW
1.243 kWh
0.000 kW
7.456 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.278 1.219 0.980 10.619
03 - 202224****** IQ7+M [5] VCOP 0.000 0.281 1.270 1.019 10.994
04 - 202232****** IQ7+ [5] VCOP 0.000 0.283 1.304 1.038 11.158
05 - 202244****** IQ7+M [5] VCOP 0.000 0.277 1.090 0.876 10.038
06 - 202245****** IQ7+M [5] VCOP 0.000 0.283 1.248 0.998 10.825
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.283 1.139 0.885 10.525 0.000 kW
1.150 kWh
0.000 kW
5.748 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.294 1.147 0.903 10.356
09 - 202217****** IQ7+ [5] VCOP 0.000 0.292 1.144 0.895 10.378
10 - 202244****** IQ7+M [5] VCOP 0.000 0.290 1.152 0.897 10.520
11 - 202224****** IQ7+M [5] VCOP 0.000 0.294 1.165 0.903 10.688
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.234 1.343 1.117 10.059 0.000 kW
1.395 kWh
0.000 kW
5.582 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.238 1.388 1.166 10.216
14 - 202216****** IQ7+ [5] VCOP 0.000 0.239 1.429 1.206 10.757
15 - 202245****** IQ7+M [5] VCOP 0.000 0.242 1.423 1.208 10.759
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.077 kW
1.831 kWh
0.230 kW
5.494 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.230 0.230 5.494 5.508 10.900
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_all.png". Check that the process running PHP has enough permission.