Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.614 kW
07/02/2026 15:23 (2227 days) Production Consumption NET Usage
Now 3.598 kW 1.984 kW -1.614 kW
Today 25.391 kWh (1.645 kW) 22.581 kWh (1.463 kW) -2.810 kWh (-0.182 kW)
  - This Week 132.623 kWh (28.571 kWh/day) 138.872 kWh (29.918 kWh/day) 6.249 kWh (1.346 kWh/day)
  - This Month 51.022 kWh (31.065 kWh/day) 64.732 kWh (39.412 kWh/day) 13.710 kWh (8.347 kWh/day)
  - This Year 3.661 MWh (20.044 kWh/day) 3.352 MWh (18.350 kWh/day) -0.309 MWh (-1.694 kWh/day)
Yesterday 25.631 kWh (1.069 kW) 42.151 kWh (1.757 kW) 16.520 kWh (0.689 kW)
Last 7 Days 167.751 kWh (23.964 kWh/day) 185.140 kWh (26.449 kWh/day) 17.389 kWh (2.484 kWh/day)
Last 30 Days (06/02/2026) 862.180 kWh (28.739 kWh/day) 763.315 kWh (25.444 kWh/day) -98.865 kWh (-3.295 kWh/day)
Last One Year 6.712 MWh (18.389 kWh/day) 7.739 MWh (21.203 kWh/day) 1.027 MWh (2.815 kWh/day)
Lifetime Since PTO 39.227 MWh (17.609 kW/day) 42.862 MWh (19.241 kW/day) 3.636 MWh (1.632 kW/day)
Lifetime Since Install 39.260 MWh 43.442 MWh 4.182 MWh
Voltage/Current 247.9 V / 14.5 A 247.9 V / 8.0 A 247.9 V / -6.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/27/2024 23:27 (14.2 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 29.193 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.284 2.051 2.089 9.229 0.000 kW
1.963 kWh
0.000 kW
11.781 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.269 1.936 1.939 8.661
03 - 202224****** IQ7+M [5] VCOP 0.000 0.278 1.997 1.997 8.947
04 - 202232****** IQ7+ [5] VCOP 0.000 0.284 2.030 2.049 9.077
05 - 202244****** IQ7+M [5] VCOP 0.000 0.268 1.799 1.783 8.165
06 - 202245****** IQ7+M [5] VCOP 0.000 0.274 1.967 1.992 8.833
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.283 1.924 1.897 8.351 0.000 kW
1.913 kWh
0.000 kW
9.566 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.283 1.891 1.886 8.337
09 - 202217****** IQ7+ [5] VCOP 0.000 0.277 1.891 1.879 8.326
10 - 202244****** IQ7+M [5] VCOP 0.000 0.276 1.911 1.890 8.375
11 - 202224****** IQ7+M [5] VCOP 0.000 0.284 1.948 1.932 8.479
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.244 1.899 1.992 8.597 0.000 kW
1.962 kWh
0.000 kW
7.846 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.252 1.919 2.027 8.896
14 - 202216****** IQ7+ [5] VCOP 0.000 0.256 2.012 2.087 9.250
15 - 202245****** IQ7+M [5] VCOP 0.000 0.258 2.017 2.089 9.246
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.20 V Current/Power -1.80 A (-95 W)
Remain Capacity/Energy 524.5 Ah (26.9 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 88.4 % State Of Health 98.9 %
Run Time 12d 3h 25m to empty Report Date 2024-07-27 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.