Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.130 kW
07/02/2026 15:33 (2227 days) Production Consumption NET Usage
Now 3.487 kW 3.357 kW -0.130 kW
Today 25.941 kWh (1.664 kW) 22.898 kWh (1.469 kW) -3.043 kWh (-0.195 kW)
  - This Week 133.173 kWh (28.650 kWh/day) 139.189 kWh (29.944 kWh/day) 6.016 kWh (1.294 kWh/day)
  - This Month 51.572 kWh (31.278 kWh/day) 65.049 kWh (39.451 kWh/day) 13.477 kWh (8.174 kWh/day)
  - This Year 3.661 MWh (20.046 kWh/day) 3.352 MWh (18.351 kWh/day) -0.310 MWh (-1.695 kWh/day)
Yesterday 25.631 kWh (1.069 kW) 42.151 kWh (1.757 kW) 16.520 kWh (0.689 kW)
Last 7 Days 168.079 kWh (24.011 kWh/day) 185.176 kWh (26.454 kWh/day) 17.097 kWh (2.442 kWh/day)
Last 30 Days (06/02/2026) 862.231 kWh (28.741 kWh/day) 763.674 kWh (25.456 kWh/day) -98.557 kWh (-3.285 kWh/day)
Last One Year 6.712 MWh (18.389 kWh/day) 7.739 MWh (21.204 kWh/day) 1.028 MWh (2.815 kWh/day)
Lifetime Since PTO 39.227 MWh (17.609 kW/day) 42.863 MWh (19.241 kW/day) 3.636 MWh (1.632 kW/day)
Lifetime Since Install 39.261 MWh 43.443 MWh 4.182 MWh
Voltage/Current 247.9 V / 14.1 A 247.8 V / 13.5 A 247.9 V / -0.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/10/2024 23:57 (23.9 hours) Number of Devices 18 set
Current Power 0.229 kW (0.013 kW/panel) Today Energy 34.481 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.286 2.058 1.749 12.601 0.000 kW
1.977 kWh
0.000 kW
11.860 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.281 1.939 1.637 11.895
03 - 202224****** IQ7+M [5] VCOP 0.000 0.282 1.991 1.671 12.194
04 - 202232****** IQ7+ [5] VCOP 0.000 0.289 2.033 1.715 12.419
05 - 202244****** IQ7+M [5] VCOP 0.000 0.275 1.845 1.482 11.095
06 - 202245****** IQ7+M [5] VCOP 0.000 0.279 1.993 1.679 12.162
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.280 1.935 1.560 11.595 0.000 kW
1.918 kWh
0.000 kW
9.590 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.282 1.851 1.571 11.340
09 - 202217****** IQ7+ [5] VCOP 0.000 0.282 1.887 1.558 11.407
10 - 202244****** IQ7+M [5] VCOP 0.000 0.279 1.934 1.551 11.561
11 - 202224****** IQ7+M [5] VCOP 0.000 0.284 1.984 1.579 11.791
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.256 1.818 1.706 11.319 0.000 kW
1.884 kWh
0.000 kW
7.534 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.270 1.814 1.777 11.553
14 - 202216****** IQ7+ [5] VCOP 0.000 0.275 1.948 1.833 12.121
15 - 202245****** IQ7+M [5] VCOP 0.000 0.277 1.953 1.832 12.126
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.076 kW
1.832 kWh
0.229 kW
5.496 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.229 0.230 5.496 5.499 38.462
Panel Layout Each Group Production

Battery History
Voltage 53.14 V Current/Power -6.18 A (-0.328 kW)
Remain Capacity/Energy 517.5 Ah (26.5 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 87.3 % State Of Health 98.9 %
Run Time 3d 11h 44m to empty Report Date 2024-07-10 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.