Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.595 kW
07/02/2026 16:22 (2227 days) Production Consumption NET Usage
Now 3.126 kW 1.531 kW -1.595 kW
Today 28.703 kWh (1.749 kW) 24.657 kWh (1.502 kW) -4.046 kWh (-0.246 kW)
  - This Week 135.935 kWh (29.029 kWh/day) 140.948 kWh (30.099 kWh/day) 5.013 kWh (1.071 kWh/day)
  - This Month 54.334 kWh (32.276 kWh/day) 66.808 kWh (39.686 kWh/day) 12.474 kWh (7.410 kWh/day)
  - This Year 3.664 MWh (20.058 kWh/day) 3.354 MWh (18.357 kWh/day) -0.311 MWh (-1.700 kWh/day)
Yesterday 25.631 kWh (1.069 kW) 42.151 kWh (1.757 kW) 16.520 kWh (0.689 kW)
Last 7 Days 168.486 kWh (24.069 kWh/day) 185.644 kWh (26.521 kWh/day) 17.158 kWh (2.451 kWh/day)
Last 30 Days (06/02/2026) 862.661 kWh (28.755 kWh/day) 765.518 kWh (25.517 kWh/day) -97.143 kWh (-3.238 kWh/day)
Last One Year 6.712 MWh (18.390 kWh/day) 7.740 MWh (21.205 kWh/day) 1.027 MWh (2.815 kWh/day)
Lifetime Since PTO 39.230 MWh (17.610 kW/day) 42.864 MWh (19.242 kW/day) 3.635 MWh (1.632 kW/day)
Lifetime Since Install 39.264 MWh 43.444 MWh 4.181 MWh
Voltage/Current 248.7 V / 12.6 A 248.6 V / 6.2 A 248.6 V / -6.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/02/2024 23:54 (23.9 hours) Number of Devices 18 set
Current Power 0.230 kW (0.013 kW/panel) Today Energy 33.680 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.284 2.029 1.626 12.351 0.000 kW
1.984 kWh
0.000 kW
11.905 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.272 1.934 1.557 11.702
03 - 202224****** IQ7+M [5] VCOP 0.000 0.283 2.006 1.602 12.154
04 - 202232****** IQ7+ [5] VCOP 0.000 0.288 2.033 1.624 12.358
05 - 202244****** IQ7+M [5] VCOP 0.000 0.273 1.933 1.466 11.106
06 - 202245****** IQ7+M [5] VCOP 0.000 0.277 1.970 1.580 11.791
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.292 2.052 1.516 11.723 0.000 kW
2.015 kWh
0.000 kW
10.077 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.293 1.969 1.442 11.616
09 - 202217****** IQ7+ [5] VCOP 0.000 0.290 1.965 1.442 11.547
10 - 202244****** IQ7+M [5] VCOP 0.000 0.287 2.012 1.494 11.723
11 - 202224****** IQ7+M [5] VCOP 0.000 0.295 2.079 1.540 11.989
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.238 1.506 1.393 10.822 0.000 kW
1.550 kWh
0.000 kW
6.201 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.246 1.489 1.415 10.977
14 - 202216****** IQ7+ [5] VCOP 0.000 0.249 1.605 1.480 11.546
15 - 202245****** IQ7+M [5] VCOP 0.000 0.250 1.602 1.480 11.530
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.077 kW
1.832 kWh
0.230 kW
5.496 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.230 0.230 5.496 5.434 5.849
Panel Layout Each Group Production

Battery History
Voltage 52.64 V Current/Power -99.77 A (-5.252 kW)
Remain Capacity/Energy 491.7 Ah (25.2 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 82.9 % State Of Health 98.9 %
Run Time 4h 55m to empty Report Date 2024-05-02 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.