Importing from grid by 1.858 kW
07/02/2026 18:34 (2227 days) Production Consumption NET Usage
Now 1.254 kW 3.112 kW 1.858 kW
Today 33.721 kWh (1.813 kW) 28.678 kWh (1.542 kW) -5.043 kWh (-0.271 kW)
  - This Week 140.953 kWh (29.525 kWh/day) 144.969 kWh (30.366 kWh/day) 4.016 kWh (0.841 kWh/day)
  - This Month 59.352 kWh (33.445 kWh/day) 70.829 kWh (39.913 kWh/day) 11.477 kWh (6.467 kWh/day)
  - This Year 3.669 MWh (20.075 kWh/day) 3.358 MWh (18.370 kWh/day) -0.312 MWh (-1.705 kWh/day)
Yesterday 25.631 kWh (1.069 kW) 42.151 kWh (1.757 kW) 16.520 kWh (0.689 kW)
Last 7 Days 170.386 kWh (24.341 kWh/day) 186.627 kWh (26.661 kWh/day) 16.241 kWh (2.320 kWh/day)
Last 30 Days (06/02/2026) 863.947 kWh (28.798 kWh/day) 770.217 kWh (25.674 kWh/day) -93.730 kWh (-3.124 kWh/day)
Last One Year 6.713 MWh (18.393 kWh/day) 7.738 MWh (21.200 kWh/day) 1.025 MWh (2.807 kWh/day)
Lifetime Since PTO 39.235 MWh (17.612 kW/day) 42.868 MWh (19.243 kW/day) 3.634 MWh (1.631 kW/day)
Lifetime Since Install 39.269 MWh 43.448 MWh 4.180 MWh
Voltage/Current 247.7 V / 5.1 A 247.6 V / 12.6 A 247.6 V / 7.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/07/2024 23:57 (23.9 hours) Number of Devices 18 set
Current Power 0.230 kW (0.013 kW/panel) Today Energy 29.763 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.738 1.261 6.398 0.000 kW
1.703 kWh
0.000 kW
10.217 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.292 1.675 1.223 6.128
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.719 1.261 6.379
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.721 1.250 6.371
05 - 202244****** IQ7+M [5] VCOP 0.000 0.291 1.669 1.200 5.914
06 - 202245****** IQ7+M [5] VCOP 0.000 0.293 1.696 1.226 6.087
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.852 1.206 6.025 0.000 kW
1.812 kWh
0.000 kW
9.062 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.785 1.208 6.124
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.740 1.191 6.087
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.823 1.225 6.151
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.863 1.241 6.209
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.260 1.206 1.137 5.517 0.000 kW
1.247 kWh
0.000 kW
4.987 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.284 1.207 1.188 5.749
14 - 202216****** IQ7+ [5] VCOP 0.000 0.267 1.295 1.223 5.996
15 - 202245****** IQ7+M [5] VCOP 0.000 0.278 1.280 1.223 5.961
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.077 kW
1.832 kWh
0.230 kW
5.497 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.230 0.230 5.497 5.477 32.944
Panel Layout Each Group Production

Battery History
Voltage 52.54 V Current/Power -6.29 A (-0.330 kW)
Remain Capacity/Energy 211.6 Ah (10.8 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 35.7 % State Of Health 98.9 %
Run Time 1d 9h 38m to empty Report Date 2024-04-07 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack