Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.005 kW
05/15/2026 09:57 (2179 days) Production Consumption NET Usage
Now 1.475 kW 0.470 kW -1.005 kW
Today 3.985 kWh (0.400 kW) 2.667 kWh (0.268 kW) -1.318 kWh (-0.132 kW)
  - This Week 133.513 kWh (24.655 kWh/day) 68.819 kWh (12.708 kWh/day) -64.694 kWh (-11.947 kWh/day)
  - This Month 351.588 kWh (24.391 kWh/day) 185.956 kWh (12.900 kWh/day) -165.632 kWh (-11.490 kWh/day)
  - This Year 2.305 MWh (17.146 kWh/day) 2.246 MWh (16.707 kWh/day) -0.059 MWh (-0.439 kWh/day)
Yesterday 22.227 kWh (0.926 kW) 14.790 kWh (0.616 kW) -7.437 kWh (-0.310 kW)
Last 7 Days 160.441 kWh (22.920 kWh/day) 131.273 kWh (18.753 kWh/day) -29.168 kWh (-4.167 kWh/day)
Last 30 Days (04/15/2026) 692.754 kWh (23.092 kWh/day) 414.940 kWh (13.831 kWh/day) -277.814 kWh (-9.260 kWh/day)
Last One Year 6.332 MWh (17.348 kWh/day) 7.792 MWh (21.349 kWh/day) 1.460 MWh (4.001 kWh/day)
Lifetime Since PTO 37.870 MWh (17.376 kW/day) 41.756 MWh (19.159 kW/day) 3.886 MWh (1.783 kW/day)
Lifetime Since Install 37.904 MWh 42.336 MWh 4.432 MWh
Voltage/Current 250.3 V / 5.9 A 250.4 V / 1.9 A 250.3 V / -4.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 02/08/2024 23:37 (10.2 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 16.357 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.227 1.196 1.330 7.105 0.000 kW
1.163 kWh
0.000 kW
6.980 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.217 1.136 1.255 6.737
03 - 202224****** IQ7+M [5] VCOP 0.000 0.225 1.176 1.292 6.956
04 - 202232****** IQ7+ [5] VCOP 0.000 0.226 1.179 1.297 6.941
05 - 202244****** IQ7+M [5] VCOP 0.000 0.218 1.136 1.258 6.752
06 - 202245****** IQ7+M [5] VCOP 0.000 0.220 1.158 1.299 6.897
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.268 1.147 1.390 7.400 0.000 kW
1.310 kWh
0.000 kW
6.550 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.272 1.305 1.566 8.290
09 - 202217****** IQ7+ [5] VCOP 0.000 0.268 1.391 1.653 8.856
10 - 202244****** IQ7+M [5] VCOP 0.000 0.266 1.371 1.630 8.713
11 - 202224****** IQ7+M [5] VCOP 0.000 0.270 1.335 1.600 8.517
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.122 0.643 0.632 3.387 0.000 kW
0.707 kWh
0.000 kW
2.828 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.127 0.711 0.715 3.902
14 - 202216****** IQ7+ [5] VCOP 0.000 0.131 0.739 0.745 4.065
15 - 202245****** IQ7+M [5] VCOP 0.000 0.130 0.735 0.739 4.030
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 21.971
Panel Layout Each Group Production

Battery History
Voltage 52.77 V Current/Power -12.21 A (-0.644 kW)
Remain Capacity/Energy 375.4 Ah (19.2 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 63.3 % State Of Health 98.9 %
Run Time 1d 6h 44m to empty Report Date 2024-02-08 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.