Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
---|
Importing from grid by 0.726 kW | |||
---|---|---|---|
07/07/2025 23:39 (1867 days) | Production | Consumption | NET Usage |
Now | 0.000 kW | 0.726 kW | 0.726 kW |
Today | 17.671 kWh (0.746 kW) | 61.893 kWh (2.614 kW) | 44.222 kWh (1.868 kW) |
- This Week | 49.303 kWh (24.813 kWh/day) | 111.049 kWh (55.889 kWh/day) | 61.746 kWh (31.076 kWh/day) |
- This Month | 179.012 kWh (25.622 kWh/day) | 279.775 kWh (40.045 kWh/day) | 100.763 kWh (14.422 kWh/day) |
- This Year | 3.209 MWh (17.069 kWh/day) | 3.407 MWh (18.124 kWh/day) | 0.198 MWh (1.055 kWh/day) |
Yesterday | 31.632 kWh (1.317 kW) | 49.156 kWh (2.047 kW) | 17.524 kWh (0.730 kW) |
Last 7 Days | 188.669 kWh (26.953 kWh/day) | 248.545 kWh (35.507 kWh/day) | 59.876 kWh (8.554 kWh/day) |
Last 30 Days | 624.655 kWh (20.822 kWh/day) | 875.653 kWh (29.189 kWh/day) | 250.998 kWh (8.367 kWh/day) |
Last One Year | 6.319 MWh (17.313 kWh/day) | 6.442 MWh (17.650 kWh/day) | 0.123 MWh (0.336 kWh/day) |
Lifetime Since PTO | 32.660 MWh (17.484 kW/day) | 35.359 MWh (18.929 kW/day) | 2.699 MWh (1.445 kW/day) |
Lifetime Since Install | 32.694 MWh | 35.939 MWh | 3.245 MWh |
Voltage/Current | 252.0 V / 0.0 A | 251.9 V / 2.9 A | 252.0 V / 2.9 A |
![]() ![]() ![]() ![]() |
Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Recent Report Data/Time | 03/31/2023 22:45 (13.8 hours) | Number of Devices | 16 set | |||||||
Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 20.093 kWh | |||||||
Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
porch | 01 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.287 | 1.201 | 2.194 | 9.836 | 0.000 kW 1.169 kWh |
0.000 kW 7.012 kWh |
02 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.272 | 1.139 | 2.128 | 9.430 | |||
03 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.281 | 1.196 | 2.194 | 9.806 | |||
04 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.281 | 1.199 | 2.193 | 9.829 | |||
05 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.270 | 1.125 | 2.054 | 9.138 | |||
06 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.274 | 1.152 | 2.079 | 9.284 | |||
front | 07 - 202206****** | IQ7+ | [0] ---- | 0.000 | 0.295 | 1.205 | 2.102 | 9.326 | 0.000 kW 1.221 kWh |
0.000 kW 6.103 kWh |
08 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.297 | 1.219 | 2.208 | 9.849 | |||
09 - 202217****** | IQ7+ | [0] ---- | 0.000 | 0.298 | 1.205 | 2.173 | 9.774 | |||
10 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.294 | 1.232 | 2.259 | 9.982 | |||
11 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.299 | 1.242 | 2.282 | 10.075 | |||
back | 12 - 202211****** | IQ7+ | [0] ---- | 0.000 | 0.216 | 0.928 | 1.674 | 7.717 | 0.000 kW 0.987 kWh |
0.000 kW 3.947 kWh |
13 - 202223****** | IQ7+ | [0] ---- | 0.000 | 0.224 | 0.957 | 1.695 | 7.941 | |||
14 - 202216****** | IQ7+ | [0] ---- | 0.000 | 0.228 | 1.030 | 1.785 | 8.330 | |||
15 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.233 | 1.032 | 1.774 | 8.303 | |||
wind | 16 - 122214****** | IQ7PD | [0] ---- | 0.000 | 0.235 | 3.031 | 2.893 | 22.240 | 0.000 kW 3.031 kWh |
0.000 kW 3.031 kWh |
![]() ![]() |
Battery History | |||
---|---|---|---|
Voltage | 52.70 V | Current/Power | -1.50 A (-79 W) |
Remain Capacity/Energy | 337.5 Ah (17.3 kWh) | Full Capacity/Energy | 600.0 Ah (30.7 kWh) |
State Of Charge | 56.3 % | State Of Health | 100.0 % |
Run Time | 9d 9h 0m to empty | Report Date | 2023-03-31 23:57 |
![]() ![]() ![]() |
Voltage | 52.72 V | Cell (MIN/MAX) | 3.286 V / 3.304 V (0.018 V) |
---|---|---|---|
Current/Power | -0.45 A (-23 W) | Runtime | 10d 10h 0m to empty |
Remain Capacity/Energy | 112.5 Ah (5.8 kWh) | Full Capacity/Energy | 200.0 Ah (10.2 kWh) |
State Of Charge | 56.2 % | State Of Health | 100.0 % |
Temperature | 18.0 °C | Cycle | 93 |
MOSFET | CFET = ON, DFET = ON | Reported | 2023-03-31 23:57 |
Voltage | 52.68 V | Cell (MIN/MAX) | 3.290 V / 3.293 V (0.003 V) |
---|---|---|---|
Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
Remain Capacity/Energy | 81.5 Ah (4.2 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
State Of Charge | 82.0 % | State Of Health | 99.5 % |
Temperature | 18.8 °C | Cycle | 38 |
MOSFET | CFET = ON, DFET = ON | Reported | 2023-03-31 23:55 |
Voltage | 52.72 V | Cell (MIN/MAX) | 3.293 V / 3.296 V (0.003 V) |
---|---|---|---|
Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
Remain Capacity/Energy | 79.4 Ah (4.1 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
State Of Charge | 79.8 % | State Of Health | 99.5 % |
Temperature | 19.9 °C | Cycle | 40 |
MOSFET | CFET = ON, DFET = ON | Reported | 2023-03-31 23:56 |
Voltage | 52.70 V | Cell (MIN/MAX) | 3.292 V / 3.295 V (0.003 V) |
---|---|---|---|
Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
Remain Capacity/Energy | 78.1 Ah (4.0 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
State Of Charge | 78.5 % | State Of Health | 99.5 % |
Temperature | 20.9 °C | Cycle | 41 |
MOSFET | CFET = ON, DFET = ON | Reported | 2023-03-31 23:55 |
Voltage | 52.68 V | Cell (MIN/MAX) | 3.290 V / 3.293 V (0.003 V) |
---|---|---|---|
Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
Remain Capacity/Energy | 79.5 Ah (4.1 kWh) | Full Capacity/Energy | 99.2 Ah (5.1 kWh) |
State Of Charge | 80.1 % | State Of Health | 99.2 % |
Temperature | 19.6 °C | Cycle | 40 |
MOSFET | CFET = ON, DFET = ON | Reported | 2023-03-31 23:56 |