Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.472 kW
07/02/2026 17:23 (2227 days) Production Consumption NET Usage
Now 2.382 kW 0.910 kW -1.472 kW
Today 31.511 kWh (1.808 kW) 25.939 kWh (1.489 kW) -5.572 kWh (-0.320 kW)
  - This Week 138.743 kWh (29.364 kWh/day) 142.230 kWh (30.102 kWh/day) 3.487 kWh (0.738 kWh/day)
  - This Month 57.142 kWh (33.116 kWh/day) 68.090 kWh (39.461 kWh/day) 10.948 kWh (6.345 kWh/day)
  - This Year 3.667 MWh (20.068 kWh/day) 3.355 MWh (18.360 kWh/day) -0.312 MWh (-1.708 kWh/day)
Yesterday 25.631 kWh (1.069 kW) 42.151 kWh (1.757 kW) 16.520 kWh (0.689 kW)
Last 7 Days 169.013 kWh (24.145 kWh/day) 185.550 kWh (26.507 kWh/day) 16.537 kWh (2.362 kWh/day)
Last 30 Days (06/02/2026) 863.559 kWh (28.785 kWh/day) 766.676 kWh (25.556 kWh/day) -96.883 kWh (-3.229 kWh/day)
Last One Year 6.713 MWh (18.393 kWh/day) 7.738 MWh (21.201 kWh/day) 1.025 MWh (2.809 kWh/day)
Lifetime Since PTO 39.233 MWh (17.611 kW/day) 42.866 MWh (19.242 kW/day) 3.633 MWh (1.631 kW/day)
Lifetime Since Install 39.267 MWh 43.446 MWh 4.179 MWh
Voltage/Current 248.9 V / 9.6 A 248.8 V / 3.7 A 248.9 V / -5.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/15/2024 23:21 (19.0 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 16.762 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.286 1.060 1.746 9.969 0.000 kW
1.029 kWh
0.000 kW
6.174 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.284 1.007 1.661 9.494
03 - 202224****** IQ7+M [5] VCOP 0.000 0.291 1.041 1.719 9.821
04 - 202232****** IQ7+ [5] VCOP 0.000 0.284 1.044 1.733 9.861
05 - 202244****** IQ7+M [5] VCOP 0.000 0.284 0.999 1.628 9.323
06 - 202245****** IQ7+M [5] VCOP 0.000 0.281 1.023 1.657 9.496
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.289 1.092 1.709 9.686 0.000 kW
1.100 kWh
0.000 kW
5.500 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.290 1.103 1.845 10.447
09 - 202217****** IQ7+ [5] VCOP 0.000 0.295 1.096 1.843 10.453
10 - 202244****** IQ7+M [5] VCOP 0.000 0.290 1.098 1.842 10.472
11 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.112 1.875 10.602
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.193 0.762 1.164 6.574 0.000 kW
0.804 kWh
0.000 kW
3.216 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.199 0.796 1.219 6.931
14 - 202216****** IQ7+ [5] VCOP 0.000 0.207 0.833 1.266 7.219
15 - 202245****** IQ7+M [5] VCOP 0.000 0.202 0.825 1.254 7.149
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.624 kWh
0.000 kW
1.871 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.230 1.871 1.135 3.275
Panel Layout Each Group Production

Battery History
Voltage 52.88 V Current/Power -2.07 A (-0.109 kW)
Remain Capacity/Energy 362.7 Ah (18.6 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 61.2 % State Of Health 98.9 %
Run Time 7d 7h 14m to empty Report Date 2024-03-15 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.