Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.500 kW
11/06/2025 16:50 (1989 days) Production Consumption NET Usage
Now 0.000 kW 0.500 kW 0.500 kW
Today 11.190 kWh (0.664 kW) 6.099 kWh (0.362 kW) -5.091 kWh (-0.302 kW)
  - This Week 65.687 kWh (13.970 kWh/day) 106.432 kWh (22.636 kWh/day) 40.745 kWh (8.666 kWh/day)
  - This Month 82.625 kWh (14.490 kWh/day) 122.620 kWh (21.504 kWh/day) 39.995 kWh (7.014 kWh/day)
  - This Year 5.661 MWh (18.277 kWh/day) 6.455 MWh (20.843 kWh/day) 0.794 MWh (2.565 kWh/day)
Yesterday 13.117 kWh (0.547 kW) 43.719 kWh (1.822 kW) 30.602 kWh (1.275 kW)
Last 7 Days 84.083 kWh (12.012 kWh/day) 145.336 kWh (20.763 kWh/day) 61.253 kWh (8.751 kWh/day)
Last 30 Days 412.415 kWh (13.747 kWh/day) 500.622 kWh (16.687 kWh/day) 88.207 kWh (2.940 kWh/day)
Last One Year 6.189 MWh (16.958 kWh/day) 7.470 MWh (20.466 kWh/day) 1.281 MWh (3.508 kWh/day)
Lifetime Since PTO 35.111 MWh (17.646 kW/day) 38.408 MWh (19.303 kW/day) 3.296 MWh (1.657 kW/day)
Lifetime Since Install 35.145 MWh 38.988 MWh 3.842 MWh
Voltage/Current 251.0 V / 0.0 A 251.0 V / 2.0 A 251.0 V / 2.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/28/2023 23:43 (14.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 23.219 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VC-- 0.000 0.296 1.558 0.979 7.387 0.000 kW
1.485 kWh
0.000 kW
8.911 kWh
02 - 202244****** IQ7+M [5] VC-- 0.000 0.296 1.481 0.931 6.945
03 - 202224****** IQ7+M [5] VC-- 0.000 0.296 1.500 0.969 7.148
04 - 202232****** IQ7+ [5] VC-- 0.000 0.296 1.517 0.976 7.226
05 - 202244****** IQ7+M [5] ---- 0.000 0.296 1.334 0.920 6.549
06 - 202245****** IQ7+M [5] ---- 0.000 0.296 1.521 0.946 7.126
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.356 0.930 6.648 0.000 kW
1.364 kWh
0.000 kW
6.821 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.292 1.363 0.924 6.581
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.362 0.935 6.640
10 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.364 0.933 6.702
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.375 0.940 6.773
back 12 - 202211****** IQ7+ [5] VC-- 0.000 0.283 1.540 0.845 6.995 0.000 kW
1.588 kWh
0.000 kW
6.351 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.289 1.580 0.868 7.187
14 - 202216****** IQ7+ [5] ---- 0.000 0.287 1.611 0.914 7.495
15 - 202245****** IQ7+M [5] ---- 0.000 0.290 1.620 0.919 7.506
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.230 1.137 1.133 8.182 0.000 kW
1.137 kWh
0.000 kW
1.137 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -4.82 A (-0.256 kW)
Remain Capacity/Energy 429.8 Ah (22.0 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 71.6 % State Of Health 100.0 %
Run Time 3d 17h 9m to empty Report Date 2023-06-28 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.