Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.468 kW
11/06/2025 16:53 (1989 days) Production Consumption NET Usage
Now 0.000 kW 0.468 kW 0.468 kW
Today 11.190 kWh (0.662 kW) 6.122 kWh (0.362 kW) -5.068 kWh (-0.300 kW)
  - This Week 65.687 kWh (13.964 kWh/day) 106.455 kWh (22.630 kWh/day) 40.768 kWh (8.667 kWh/day)
  - This Month 82.625 kWh (14.484 kWh/day) 122.643 kWh (21.500 kWh/day) 40.018 kWh (7.015 kWh/day)
  - This Year 5.661 MWh (18.277 kWh/day) 6.455 MWh (20.843 kWh/day) 0.794 MWh (2.565 kWh/day)
Yesterday 13.117 kWh (0.547 kW) 43.719 kWh (1.822 kW) 30.602 kWh (1.275 kW)
Last 7 Days 84.083 kWh (12.012 kWh/day) 145.336 kWh (20.763 kWh/day) 61.253 kWh (8.751 kWh/day)
Last 30 Days 412.415 kWh (13.747 kWh/day) 500.622 kWh (16.687 kWh/day) 88.207 kWh (2.940 kWh/day)
Last One Year 6.189 MWh (16.958 kWh/day) 7.470 MWh (20.466 kWh/day) 1.281 MWh (3.508 kWh/day)
Lifetime Since PTO 35.111 MWh (17.646 kW/day) 38.408 MWh (19.303 kW/day) 3.296 MWh (1.657 kW/day)
Lifetime Since Install 35.145 MWh 38.988 MWh 3.842 MWh
Voltage/Current 250.5 V / 0.0 A 250.6 V / 1.9 A 250.5 V / 1.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/18/2023 23:51 (14.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 29.696 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VC-- 0.000 0.295 2.012 1.922 11.034 0.000 kW
1.874 kWh
0.000 kW
11.246 kWh
02 - 202244****** IQ7+M [5] ---- 0.000 0.286 1.872 1.796 10.362
03 - 202224****** IQ7+M [5] VC-- 0.000 0.292 1.876 1.844 10.615
04 - 202232****** IQ7+ [0] ---- 0.000 0.294 1.913 1.855 10.730
05 - 202244****** IQ7+M [0] ---- 0.000 0.293 1.640 1.713 9.730
06 - 202245****** IQ7+M [0] -C-- 0.000 0.295 1.934 1.858 10.664
front 07 - 202206****** IQ7+ [5] ---- 0.000 0.296 1.750 1.734 9.950 0.000 kW
1.749 kWh
0.000 kW
8.744 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.296 1.726 1.741 9.826
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.737 1.746 9.981
10 - 202244****** IQ7+M [5] VC-- 0.000 0.294 1.758 1.737 10.033
11 - 202224****** IQ7+M [5] VC-- 0.000 0.295 1.774 1.759 10.152
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.288 2.049 1.766 10.345 0.000 kW
2.084 kWh
0.000 kW
8.337 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.294 2.049 1.795 10.523
14 - 202216****** IQ7+ [0] ---- 0.000 0.294 2.121 1.845 10.923
15 - 202245****** IQ7+M [0] ---- 0.000 0.294 2.118 1.844 10.938
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.230 1.369 1.353 11.101 0.000 kW
1.369 kWh
0.000 kW
1.369 kWh
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.