Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.452 kW
03/11/2026 03:04 (2114 days) Production Consumption NET Usage
Now 0.000 kW 0.452 kW 0.452 kW
Today 0.000 kWh (0.000 kW) 1.307 kWh (0.424 kW) 1.307 kWh (0.424 kW)
  - This Week 59.922 kWh (19.154 kWh/day) 43.637 kWh (13.949 kWh/day) -16.285 kWh (-5.206 kWh/day)
  - This Month 153.630 kWh (15.168 kWh/day) 149.936 kWh (14.804 kWh/day) -3.694 kWh (-0.365 kWh/day)
  - This Year 0.788 MWh (11.393 kWh/day) 1.250 MWh (18.079 kWh/day) 0.462 MWh (6.686 kWh/day)
Yesterday 23.741 kWh (0.990 kW) 14.656 kWh (0.611 kW) -9.085 kWh (-0.379 kW)
Last 7 Days 92.731 kWh (13.247 kWh/day) 105.640 kWh (15.091 kWh/day) 12.909 kWh (1.844 kWh/day)
Last 30 Days 404.395 kWh (13.480 kWh/day) 505.501 kWh (16.850 kWh/day) 101.106 kWh (3.370 kWh/day)
Last One Year 6.064 MWh (16.615 kWh/day) 7.808 MWh (21.393 kWh/day) 1.744 MWh (4.778 kWh/day)
Lifetime Since PTO 36.353 MWh (17.195 kW/day) 40.761 MWh (19.280 kW/day) 4.407 MWh (2.085 kW/day)
Lifetime Since Install 36.387 MWh 41.341 MWh 4.953 MWh
Voltage/Current 252.0 V / 0.0 A 251.9 V / 1.8 A 252.0 V / 1.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/28/2023 23:10 (11.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 8.851 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.131 0.626 1.670 5.890 0.000 kW
0.601 kWh
0.000 kW
3.607 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.127 0.592 1.601 5.618
03 - 202224****** IQ7+M [0] ---- 0.000 0.133 0.618 1.653 5.844
04 - 202232****** IQ7+ [0] ---- 0.000 0.134 0.619 1.668 5.873
05 - 202244****** IQ7+M [0] ---- 0.000 0.128 0.563 1.561 5.461
06 - 202245****** IQ7+M [0] ---- 0.000 0.131 0.588 1.589 5.588
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.145 0.563 1.535 5.456 0.000 kW
0.574 kWh
0.000 kW
2.871 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.137 0.569 1.703 5.883
09 - 202217****** IQ7+ [0] ---- 0.000 0.145 0.581 1.719 5.890
10 - 202244****** IQ7+M [0] ---- 0.000 0.133 0.577 1.704 5.858
11 - 202224****** IQ7+M [0] ---- 0.000 0.132 0.580 1.728 5.940
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.113 0.557 1.254 4.700 0.000 kW
0.593 kWh
0.000 kW
2.373 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.113 0.586 1.301 4.879
14 - 202216****** IQ7+ [0] ---- 0.000 0.117 0.615 1.345 5.085
15 - 202245****** IQ7+M [0] ---- 0.000 0.119 0.615 1.344 5.089
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 2.796
Panel Layout Each Group Production

Battery History
Voltage 52.63 V Current/Power -1.80 A (-94 W)
Remain Capacity/Energy 279.0 Ah (14.3 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 47.0 % State Of Health 98.9 %
Run Time 6d 11h 0m to empty Report Date 2023-09-28 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.