Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.488 kW
07/08/2025 16:39 (1868 days) Production Consumption NET Usage
Now 2.263 kW 2.751 kW 0.488 kW
Today 24.065 kWh (1.443 kW) 23.690 kWh (1.420 kW) -0.375 kWh (-0.022 kW)
  - This Week 73.368 kWh (27.220 kWh/day) 135.036 kWh (50.100 kWh/day) 61.668 kWh (22.880 kWh/day)
  - This Month 203.077 kWh (26.391 kWh/day) 303.762 kWh (39.476 kWh/day) 100.685 kWh (13.085 kWh/day)
  - This Year 3.233 MWh (17.132 kWh/day) 3.431 MWh (18.183 kWh/day) 0.198 MWh (1.050 kWh/day)
Yesterday 17.671 kWh (0.736 kW) 62.190 kWh (2.592 kW) 44.519 kWh (1.855 kW)
Last 7 Days 179.012 kWh (25.573 kWh/day) 280.072 kWh (40.010 kWh/day) 101.060 kWh (14.437 kWh/day)
Last 30 Days 628.494 kWh (20.950 kWh/day) 917.638 kWh (30.588 kWh/day) 289.144 kWh (9.638 kWh/day)
Last One Year 6.308 MWh (17.282 kWh/day) 6.469 MWh (17.724 kWh/day) 0.161 MWh (0.442 kWh/day)
Lifetime Since PTO 32.684 MWh (17.490 kW/day) 35.383 MWh (18.935 kW/day) 2.699 MWh (1.444 kW/day)
Lifetime Since Install 32.718 MWh 35.963 MWh 3.245 MWh
Voltage/Current 248.1 V / 9.1 A 248.1 V / 11.1 A 248.1 V / 2.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/15/2023 23:11 (9.3 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.720 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.212 1.090 0.412 3.168 0.000 kW
1.069 kWh
0.000 kW
6.416 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.208 1.036 0.383 3.010
03 - 202224****** IQ7+M [5] VCOP 0.000 0.213 1.092 0.408 3.170
04 - 202232****** IQ7+ [5] VCOP 0.000 0.211 1.076 0.403 3.140
05 - 202244****** IQ7+M [5] VCOP 0.000 0.211 1.071 0.392 3.052
06 - 202245****** IQ7+M [5] VCOP 0.000 0.206 1.052 0.396 3.026
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.273 1.183 0.408 3.191 0.000 kW
1.321 kWh
0.000 kW
6.606 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.274 1.313 0.412 3.443
09 - 202217****** IQ7+ [5] VCOP 0.000 0.275 1.410 0.407 3.566
10 - 202244****** IQ7+M [5] VCOP 0.000 0.273 1.394 0.412 3.556
11 - 202224****** IQ7+M [5] VCOP 0.000 0.272 1.306 0.403 3.407
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.090 0.372 0.350 1.932 0.000 kW
0.424 kWh
0.000 kW
1.697 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.097 0.446 0.358 2.064
14 - 202216****** IQ7+ [5] VCOP 0.000 0.097 0.452 0.356 2.079
15 - 202245****** IQ7+M [5] VCOP 0.000 0.095 0.428 0.348 2.029
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.79 V Current/Power -1.23 A (-64 W)
Remain Capacity/Energy 362.4 Ah (18.6 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 60.4 % State Of Health 100.0 %
Run Time 12d 6h 38m to empty Report Date 2023-01-15 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack


Warning: unlink(images/chart_batt1_0.png): No such file or directory in C:\wamp64\www\solar\chart_batteries.php on line 185
JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.