| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Importing from grid by 2.647 kW | |||
|---|---|---|---|
| 07/02/2026 22:11 (2227 days) | Production | Consumption | NET Usage |
| Now | 0.225 kW | 2.872 kW | 2.647 kW |
| Today | 35.238 kWh (1.586 kW) | 40.435 kWh (1.820 kW) | 5.197 kWh (0.234 kW) |
| - This Week | 142.470 kWh (28.930 kWh/day) | 156.726 kWh (31.825 kWh/day) | 14.256 kWh (2.895 kWh/day) |
| - This Month | 60.869 kWh (31.617 kWh/day) | 82.586 kWh (42.897 kWh/day) | 21.717 kWh (11.280 kWh/day) |
| - This Year | 3.671 MWh (20.067 kWh/day) | 3.369 MWh (18.419 kWh/day) | -0.301 MWh (-1.647 kWh/day) |
| Yesterday | 25.631 kWh (1.069 kW) | 42.151 kWh (1.757 kW) | 16.520 kWh (0.689 kW) |
| Last 7 Days | 171.377 kWh (24.482 kWh/day) | 193.437 kWh (27.634 kWh/day) | 22.060 kWh (3.151 kWh/day) |
| Last 30 Days (06/02/2026) | 863.779 kWh (28.793 kWh/day) | 784.347 kWh (26.145 kWh/day) | -79.432 kWh (-2.648 kWh/day) |
| Last One Year | 6.714 MWh (18.395 kWh/day) | 7.742 MWh (21.211 kWh/day) | 1.028 MWh (2.816 kWh/day) |
| Lifetime Since PTO | 39.236 MWh (17.611 kW/day) | 42.880 MWh (19.247 kW/day) | 3.644 MWh (1.635 kW/day) |
| Lifetime Since Install | 39.270 MWh | 43.460 MWh | 4.190 MWh |
| Voltage/Current | 249.4 V / 0.9 A | 249.3 V / 11.5 A | 249.3 V / 10.6 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 12/18/2023 23:49 (8.6 hours) | Number of Devices | 18 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 3.689 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.195 | 0.257 | 0.076 | 5.196 | 0.000 kW 0.254 kWh |
0.000 kW 1.521 kWh |
| 02 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.199 | 0.243 | 0.069 | 4.958 | |||
| 03 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.206 | 0.262 | 0.075 | 5.178 | |||
| 04 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.194 | 0.265 | 0.074 | 5.226 | |||
| 05 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.187 | 0.247 | 0.067 | 4.994 | |||
| 06 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.190 | 0.247 | 0.069 | 5.044 | |||
| front | 07 - 202206****** | IQ7+ | [0] ---- | 0.000 | 0.244 | 0.292 | 0.068 | 5.572 | 0.000 kW 0.304 kWh |
0.000 kW 1.519 kWh |
| 08 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.243 | 0.296 | 0.070 | 6.257 | |||
| 09 - 202217****** | IQ7+ | [0] ---- | 0.000 | 0.256 | 0.315 | 0.069 | 6.663 | |||
| 10 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.242 | 0.308 | 0.069 | 6.492 | |||
| 11 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.244 | 0.308 | 0.069 | 6.134 | |||
| back | 12 - 202211****** | IQ7+ | [0] ---- | 0.000 | 0.075 | 0.149 | 0.066 | 1.710 | 0.000 kW 0.162 kWh |
0.000 kW 0.649 kWh |
| 13 - 202223****** | IQ7+ | [0] ---- | 0.000 | 0.084 | 0.161 | 0.074 | 2.108 | |||
| 14 - 202216****** | IQ7+ | [0] ---- | 0.000 | 0.089 | 0.170 | 0.079 | 2.240 | |||
| 15 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.090 | 0.169 | 0.080 | 2.204 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.000 kWh |
0.000 kW 0.000 kWh |
| 17 - 122344****** | IQ7AS | [0] V--- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
| 18 - 122214****** | IQ7PD | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 5.658 | |||
|
||||||||||
| Battery History | |||
|---|---|---|---|
| Voltage | 52.65 V | Current/Power | -0.90 A (-47 W) |
| Remain Capacity/Energy | 329.1 Ah (16.8 kWh) | Full Capacity/Energy | 593.1 Ah (30.4 kWh) |
| State Of Charge | 55.5 % | State Of Health | 98.9 % |
| Run Time | 15d 5h 40m to empty | Report Date | 2023-12-18 23:58 |
|
|||
| Voltage | 52.62 V | Cell (MIN/MAX) | 3.281 V / 3.297 V (0.016 V) |
|---|---|---|---|
| Current/Power | -0.28 A (-14 W) | Runtime | 16d 7h 47m to empty |
| Remain Capacity/Energy | 109.7 Ah (5.6 kWh) | Full Capacity/Energy | 197.7 Ah (10.1 kWh) |
| State Of Charge | 55.5 % | State Of Health | 98.8 % |
| Temperature | 19.0 °C | Cycle | 128 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-12-18 23:58 |
| Voltage | 52.65 V | Cell (MIN/MAX) | 3.290 V / 3.292 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 68.9 Ah (3.5 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 69.2 % | State Of Health | 99.5 % |
| Temperature | 19.8 °C | Cycle | 71 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-12-18 23:56 |
| Voltage | 52.68 V | Cell (MIN/MAX) | 3.290 V / 3.293 V (0.003 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 67.9 Ah (3.5 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 68.3 % | State Of Health | 99.5 % |
| Temperature | 20.6 °C | Cycle | 74 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-12-18 23:59 |
| Voltage | 52.66 V | Cell (MIN/MAX) | 3.290 V / 3.292 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 67.2 Ah (3.4 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 67.6 % | State Of Health | 99.5 % |
| Temperature | 21.1 °C | Cycle | 76 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-12-18 23:57 |
| Voltage | 52.65 V | Cell (MIN/MAX) | 3.289 V / 3.290 V (0.001 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 67.5 Ah (3.5 kWh) | Full Capacity/Energy | 99.2 Ah (5.1 kWh) |
| State Of Charge | 68.0 % | State Of Health | 99.2 % |
| Temperature | 20.3 °C | Cycle | 74 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-12-18 23:57 |