Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.228 kW
11/06/2025 22:13 (1989 days) Production Consumption NET Usage
Now 0.000 kW 0.228 kW 0.228 kW
Today 11.190 kWh (0.503 kW) 8.974 kWh (0.403 kW) -2.216 kWh (-0.100 kW)
  - This Week 65.687 kWh (13.333 kWh/day) 109.307 kWh (22.187 kWh/day) 43.620 kWh (8.854 kWh/day)
  - This Month 82.625 kWh (13.940 kWh/day) 125.495 kWh (21.173 kWh/day) 42.870 kWh (7.233 kWh/day)
  - This Year 5.661 MWh (18.264 kWh/day) 6.458 MWh (20.837 kWh/day) 0.797 MWh (2.573 kWh/day)
Yesterday 13.117 kWh (0.547 kW) 43.719 kWh (1.822 kW) 30.602 kWh (1.275 kW)
Last 7 Days 84.083 kWh (12.012 kWh/day) 145.336 kWh (20.763 kWh/day) 61.253 kWh (8.751 kWh/day)
Last 30 Days 412.415 kWh (13.747 kWh/day) 500.622 kWh (16.687 kWh/day) 88.207 kWh (2.940 kWh/day)
Last One Year 6.189 MWh (16.958 kWh/day) 7.470 MWh (20.466 kWh/day) 1.281 MWh (3.508 kWh/day)
Lifetime Since PTO 35.111 MWh (17.644 kW/day) 38.411 MWh (19.302 kW/day) 3.299 MWh (1.658 kW/day)
Lifetime Since Install 35.145 MWh 38.991 MWh 3.845 MWh
Voltage/Current 250.4 V / 0.0 A 250.4 V / 0.9 A 250.4 V / 0.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/23/2023 22:34 (15.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 8.911 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.119 0.358 1.446 11.703 0.000 kW
0.337 kWh
0.000 kW
2.022 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.113 0.339 1.383 11.200
03 - 202224****** IQ7+M [0] ---- 0.000 0.117 0.365 1.439 11.613
04 - 202232****** IQ7+ [0] ---- 0.000 0.119 0.359 1.451 11.648
05 - 202244****** IQ7+M [0] ---- 0.000 0.098 0.295 1.381 11.011
06 - 202245****** IQ7+M [0] ---- 0.000 0.100 0.305 1.400 11.144
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.097 0.296 1.395 11.385 0.000 kW
0.310 kWh
0.000 kW
1.549 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.097 0.305 1.457 12.077
09 - 202217****** IQ7+ [0] ---- 0.000 0.098 0.316 1.462 12.056
10 - 202244****** IQ7+M [0] ---- 0.000 0.098 0.317 1.456 12.189
11 - 202224****** IQ7+M [0] ---- 0.000 0.098 0.316 1.468 12.266
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.145 0.388 1.108 8.253 0.000 kW
0.424 kWh
0.000 kW
1.697 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.151 0.417 1.161 8.596
14 - 202216****** IQ7+ [0] ---- 0.000 0.155 0.447 1.207 9.007
15 - 202245****** IQ7+M [0] ---- 0.000 0.158 0.446 1.207 8.976
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.233 3.642 3.949 25.254 0.000 kW
3.642 kWh
0.000 kW
3.642 kWh
Panel Layout Each Group Production

Battery History
Voltage 52.43 V Current/Power -4.95 A (-0.260 kW)
Remain Capacity/Energy 268.0 Ah (13.7 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 44.7 % State Of Health 100.0 %
Run Time 2d 6h 8m to empty Report Date 2023-03-23 23:58