Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 2.769 kW
07/02/2026 21:47 (2227 days) Production Consumption NET Usage
Now 0.225 kW 2.994 kW 2.769 kW
Today 35.150 kWh (1.610 kW) 39.050 kWh (1.789 kW) 3.900 kWh (0.179 kW)
  - This Week 142.382 kWh (29.008 kWh/day) 155.341 kWh (31.648 kWh/day) 12.959 kWh (2.640 kWh/day)
  - This Month 60.781 kWh (31.840 kWh/day) 81.201 kWh (42.537 kWh/day) 20.420 kWh (10.697 kWh/day)
  - This Year 3.671 MWh (20.068 kWh/day) 3.368 MWh (18.413 kWh/day) -0.303 MWh (-1.655 kWh/day)
Yesterday 25.631 kWh (1.069 kW) 42.151 kWh (1.757 kW) 16.520 kWh (0.689 kW)
Last 7 Days 171.289 kWh (24.470 kWh/day) 192.205 kWh (27.458 kWh/day) 20.916 kWh (2.988 kWh/day)
Last 30 Days (06/02/2026) 863.820 kWh (28.794 kWh/day) 783.168 kWh (26.106 kWh/day) -80.652 kWh (-2.688 kWh/day)
Last One Year 6.714 MWh (18.394 kWh/day) 7.742 MWh (21.211 kWh/day) 1.028 MWh (2.816 kWh/day)
Lifetime Since PTO 39.236 MWh (17.611 kW/day) 42.879 MWh (19.246 kW/day) 3.642 MWh (1.635 kW/day)
Lifetime Since Install 39.270 MWh 43.459 MWh 4.189 MWh
Voltage/Current 248.6 V / 0.9 A 248.6 V / 12.0 A 248.6 V / 11.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/16/2023 23:53 (15.9 hours) Number of Devices 18 set
Current Power 0.229 kW (0.013 kW/panel) Today Energy 14.306 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.198 1.009 0.983 5.577 0.000 kW
0.994 kWh
0.000 kW
5.967 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.189 0.973 0.929 5.304
03 - 202224****** IQ7+M [0] ---- 0.000 0.194 1.007 0.972 5.545
04 - 202232****** IQ7+ [0] ---- 0.000 0.194 1.010 0.975 5.576
05 - 202244****** IQ7+M [0] ---- 0.000 0.190 0.983 0.939 5.372
06 - 202245****** IQ7+M [0] ---- 0.000 0.192 0.985 0.948 5.442
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.248 1.037 0.914 5.568 0.000 kW
1.184 kWh
0.000 kW
5.920 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.248 1.174 1.073 6.219
09 - 202217****** IQ7+ [0] ---- 0.000 0.248 1.257 1.160 6.763
10 - 202244****** IQ7+M [0] ---- 0.000 0.245 1.246 1.142 6.600
11 - 202224****** IQ7+M [0] ---- 0.000 0.250 1.207 1.084 6.327
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.094 0.422 0.663 2.976 0.000 kW
0.489 kWh
0.000 kW
1.957 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.099 0.499 0.718 3.351
14 - 202216****** IQ7+ [0] ---- 0.000 0.102 0.523 0.680 3.447
15 - 202245****** IQ7+M [0] ---- 0.000 0.102 0.512 0.631 3.361
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.076 kW
0.154 kWh
0.229 kW
0.463 kWh
17 - 122344****** IQ7AS [0] V--- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.229 0.230 0.463 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.14 V Current/Power -5.41 A (-0.287 kW)
Remain Capacity/Energy 514.2 Ah (26.3 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 86.7 % State Of Health 98.9 %
Run Time 3d 23h 2m to empty Report Date 2023-11-16 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.