Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.138 kW
03/11/2026 08:15 (2114 days) Production Consumption NET Usage
Now 0.410 kW 0.272 kW -0.138 kW
Today 0.154 kWh (0.019 kW) 3.939 kWh (0.476 kW) 3.785 kWh (0.458 kW)
  - This Week 60.076 kWh (17.963 kWh/day) 46.269 kWh (13.835 kWh/day) -13.807 kWh (-4.128 kWh/day)
  - This Month 153.784 kWh (14.867 kWh/day) 152.568 kWh (14.749 kWh/day) -1.216 kWh (-0.118 kWh/day)
  - This Year 0.788 MWh (11.359 kWh/day) 1.252 MWh (18.061 kWh/day) 0.465 MWh (6.701 kWh/day)
Yesterday 23.741 kWh (0.990 kW) 14.656 kWh (0.611 kW) -9.085 kWh (-0.379 kW)
Last 7 Days 91.164 kWh (13.023 kWh/day) 106.392 kWh (15.199 kWh/day) 15.228 kWh (2.175 kWh/day)
Last 30 Days (02/09/2026) 402.742 kWh (13.425 kWh/day) 503.424 kWh (16.781 kWh/day) 100.682 kWh (3.356 kWh/day)
Last One Year 6.064 MWh (16.614 kWh/day) 7.808 MWh (21.391 kWh/day) 1.743 MWh (4.776 kWh/day)
Lifetime Since PTO 36.353 MWh (17.194 kW/day) 40.763 MWh (19.279 kW/day) 4.410 MWh (2.086 kW/day)
Lifetime Since Install 36.387 MWh 41.343 MWh 4.956 MWh
Voltage/Current 248.2 V / 1.7 A 248.1 V / 1.1 A 248.1 V / -0.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/08/2023 23:36 (14.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.055 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.293 0.979 1.356 11.989 0.000 kW
0.939 kWh
0.000 kW
5.631 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.270 0.924 1.293 11.332
03 - 202224****** IQ7+M [5] VCOP 0.000 0.290 0.959 1.338 11.639
04 - 202232****** IQ7+ [5] VCOP 0.000 0.278 0.967 1.352 11.826
05 - 202244****** IQ7+M [5] VCOP 0.000 0.293 0.858 1.283 10.747
06 - 202245****** IQ7+M [5] VCOP 0.000 0.274 0.945 1.314 11.630
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.290 0.857 1.267 10.975 0.000 kW
0.865 kWh
0.000 kW
4.326 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 0.856 1.273 10.809
09 - 202217****** IQ7+ [5] VCOP 0.000 0.291 0.866 1.274 10.908
10 - 202244****** IQ7+M [5] VCOP 0.000 0.289 0.869 1.269 10.994
11 - 202224****** IQ7+M [5] VCOP 0.000 0.291 0.878 1.284 11.185
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.255 0.945 1.190 10.981 0.000 kW
0.991 kWh
0.000 kW
3.963 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.262 0.983 1.233 11.150
14 - 202216****** IQ7+ [5] VCOP 0.000 0.271 1.015 1.264 11.542
15 - 202245****** IQ7+M [5] VCOP 0.000 0.265 1.020 1.271 11.592
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.568 kWh
0.000 kW
1.135 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.230 1.135 1.129 8.601
Panel Layout Each Group Production

Battery History
Voltage 52.66 V Current/Power -9.04 A (-0.476 kW)
Remain Capacity/Energy 347.8 Ah (17.8 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 58.6 % State Of Health 98.9 %
Run Time 1d 14h 28m to empty Report Date 2023-07-08 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.66 V Cell (MIN/MAX) 3.280 V / 3.309 V (0.029 V)
Current/Power -5.15 A (-271 W) Runtime 22h 30m to empty
Remain Capacity/Energy 115.9 Ah (5.9 kWh) Full Capacity/Energy 197.7 Ah (10.1 kWh)
State Of Charge 58.6 % State Of Health 98.8 %
Temperature 25.5 °C Cycle 109
MOSFET CFET = ON, DFET = ON Reported 2023-07-08 23:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.280 V 3.281 V 3.280 V 3.283 V 3.290 V 3.282 V 3.284 V 3.287 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.299 V 3.290 V 3.297 V 3.289 V 3.300 V 3.303 V 3.309 V 3.303 V
pack voltage and current cell voltages
pack temperature
Voltage 52.62 V Cell (MIN/MAX) 3.287 V / 3.291 V (0.004 V)
Current/Power -1.73 A (-90 W) Runtime 1d 15h 46m to empty
Remain Capacity/Energy 68.7 Ah (3.5 kWh) Full Capacity/Energy 99.5 Ah (5.1 kWh)
State Of Charge 69.1 % State Of Health 99.5 %
Temperature 24.6 °C Cycle 54
MOSFET CFET = ON, DFET = ON Reported 2023-07-08 23:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.288 V 3.287 V 3.289 V 3.287 V 3.290 V 3.290 V 3.287 V 3.291 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.287 V 3.287 V 3.289 V 3.288 V 3.289 V 3.288 V 3.289 V 3.288 V
pack voltage and current cell voltages
pack temperature
Voltage 52.67 V Cell (MIN/MAX) 3.290 V / 3.293 V (0.003 V)
Current/Power -1.10 A (-57 W) Runtime 2d 13h 5m to empty
Remain Capacity/Energy 67.2 Ah (3.4 kWh) Full Capacity/Energy 99.5 Ah (5.1 kWh)
State Of Charge 67.6 % State Of Health 99.5 %
Temperature 25.9 °C Cycle 57
MOSFET CFET = ON, DFET = ON Reported 2023-07-08 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.292 V 3.292 V 3.292 V 3.290 V 3.292 V 3.291 V 3.293 V 3.293 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.292 V 3.293 V 3.291 V 3.292 V 3.291 V 3.290 V 3.291 V 3.290 V
pack voltage and current cell voltages
pack temperature
Voltage 52.64 V Cell (MIN/MAX) 3.288 V / 3.291 V (0.003 V)
Current/Power -1.32 A (-69 W) Runtime 2d 2h 29m to empty
Remain Capacity/Energy 66.9 Ah (3.4 kWh) Full Capacity/Energy 99.5 Ah (5.1 kWh)
State Of Charge 67.3 % State Of Health 99.5 %
Temperature 26.5 °C Cycle 59
MOSFET CFET = ON, DFET = ON Reported 2023-07-08 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.288 V 3.291 V 3.288 V 3.291 V 3.289 V 3.290 V 3.290 V 3.289 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.288 V 3.289 V 3.290 V 3.289 V 3.291 V 3.290 V 3.290 V 3.290 V
pack voltage and current cell voltages
pack temperature
Voltage 52.64 V Cell (MIN/MAX) 3.288 V / 3.291 V (0.003 V)
Current/Power -1.13 A (-59 W) Runtime 2d 11h 30m to empty
Remain Capacity/Energy 67.2 Ah (3.4 kWh) Full Capacity/Energy 99.2 Ah (5.1 kWh)
State Of Charge 67.8 % State Of Health 99.2 %
Temperature 24.9 °C Cycle 57
MOSFET CFET = ON, DFET = ON Reported 2023-07-08 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.288 V 3.291 V 3.289 V 3.290 V 3.290 V 3.290 V 3.289 V 3.291 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.289 V 3.290 V 3.289 V 3.289 V 3.290 V 3.290 V 3.290 V 3.290 V
pack voltage and current cell voltages
pack temperature