Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.732 kW
01/13/2026 11:58 (2057 days) Production Consumption NET Usage
Now 2.783 kW 0.051 kW -2.732 kW
Today 6.065 kWh (0.506 kW) 6.557 kWh (0.547 kW) 0.492 kWh (0.041 kW)
  - This Week 30.104 kWh (12.046 kWh/day) 39.120 kWh (15.653 kWh/day) 9.016 kWh (3.608 kWh/day)
  - This Month 105.915 kWh (8.473 kWh/day) 237.854 kWh (19.029 kWh/day) 131.939 kWh (10.555 kWh/day)
  - This Year 0.106 MWh (8.473 kWh/day) 0.238 MWh (19.029 kWh/day) 0.132 MWh (10.555 kWh/day)
Yesterday 14.545 kWh (0.606 kW) 16.751 kWh (0.698 kW) 2.206 kWh (0.092 kW)
Last 7 Days 58.918 kWh (8.417 kWh/day) 155.903 kWh (22.272 kWh/day) 96.985 kWh (13.855 kWh/day)
Last 30 Days 224.926 kWh (7.497 kWh/day) 612.416 kWh (20.413 kWh/day) 387.490 kWh (12.916 kWh/day)
Last One Year 6.097 MWh (16.705 kWh/day) 7.473 MWh (20.475 kWh/day) 1.376 MWh (3.770 kWh/day)
Lifetime Since PTO 35.672 MWh (17.337 kW/day) 39.749 MWh (19.319 kW/day) 4.078 MWh (1.982 kW/day)
Lifetime Since Install 35.706 MWh 40.329 MWh 4.624 MWh
Voltage/Current 251.4 V / 11.1 A 251.5 V / 0.2 A 251.4 V / -10.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/30/2023 22:52 (12.0 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 3.680 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.092 0.259 0.300 7.350 0.000 kW
0.249 kWh
0.000 kW
1.491 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.087 0.242 0.278 6.996
03 - 202224****** IQ7+M [5] VCOP 0.000 0.091 0.257 0.297 7.261
04 - 202232****** IQ7+ [5] VCOP 0.000 0.088 0.255 0.295 7.334
05 - 202244****** IQ7+M [5] VCOP 0.000 0.085 0.235 0.271 6.685
06 - 202245****** IQ7+M [5] VCOP 0.000 0.088 0.243 0.279 7.018
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.081 0.232 0.269 6.870 0.000 kW
0.234 kWh
0.000 kW
1.172 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.079 0.235 0.272 6.820
09 - 202217****** IQ7+ [5] VCOP 0.000 0.081 0.236 0.273 6.839
10 - 202244****** IQ7+M [5] VCOP 0.000 0.084 0.236 0.274 6.959
11 - 202224****** IQ7+M [5] VCOP 0.000 0.084 0.234 0.272 7.068
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.084 0.230 0.264 6.726 0.000 kW
0.254 kWh
0.000 kW
1.017 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.088 0.249 0.288 6.929
14 - 202216****** IQ7+ [5] VCOP 0.000 0.092 0.270 0.310 7.208
15 - 202245****** IQ7+M [5] VCOP 0.000 0.091 0.269 0.310 7.206
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 9.257
Panel Layout Each Group Production

Battery History
Voltage 52.46 V Current/Power -1.50 A (-78 W)
Remain Capacity/Energy 214.8 Ah (11.0 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 35.8 % State Of Health 100.0 %
Run Time 5d 23h 12m to empty Report Date 2023-04-30 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack