Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.055 kW
09/12/2025 08:08 (1934 days) Production Consumption NET Usage
Now 0.442 kW 0.497 kW 0.055 kW
Today 0.317 kWh (0.039 kW) 4.113 kWh (0.503 kW) 3.796 kWh (0.465 kW)
  - This Week 105.804 kWh (19.814 kWh/day) 72.208 kWh (13.523 kWh/day) -33.596 kWh (-6.292 kWh/day)
  - This Month 242.732 kWh (21.406 kWh/day) 267.933 kWh (23.628 kWh/day) 25.201 kWh (2.222 kWh/day)
  - This Year 4.750 MWh (18.676 kWh/day) 5.439 MWh (21.384 kWh/day) 0.689 MWh (2.707 kWh/day)
Yesterday 26.396 kWh (1.101 kW) 14.540 kWh (0.606 kW) -11.856 kWh (-0.494 kW)
Last 7 Days 143.227 kWh (20.460 kWh/day) 158.213 kWh (22.601 kWh/day) 14.986 kWh (2.141 kWh/day)
Last 30 Days 685.205 kWh (22.841 kWh/day) 773.641 kWh (25.789 kWh/day) 88.436 kWh (2.948 kWh/day)
Last One Year 6.279 MWh (17.202 kWh/day) 7.076 MWh (19.386 kWh/day) 0.797 MWh (2.184 kWh/day)
Lifetime Since PTO 34.201 MWh (17.681 kW/day) 37.391 MWh (19.330 kW/day) 3.190 MWh (1.649 kW/day)
Lifetime Since Install 34.235 MWh 37.971 MWh 3.736 MWh
Voltage/Current 253.2 V / 1.7 A 253.3 V / 2.0 A 253.3 V / 0.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/26/2022 22:32 (8.8 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 13.001 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.204 0.987 1.037 4.961 0.000 kW
0.963 kWh
0.000 kW
5.780 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.198 0.938 0.985 4.733
03 - 202224****** IQ7+M [5] VCOP 0.000 0.203 0.989 1.032 4.969
04 - 202232****** IQ7+ [5] VCOP 0.000 0.201 0.967 1.030 4.949
05 - 202244****** IQ7+M [5] VCOP 0.000 0.202 0.970 1.010 4.862
06 - 202245****** IQ7+M [5] VCOP 0.000 0.197 0.928 0.987 4.729
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.258 1.002 1.121 5.111 0.000 kW
1.146 kWh
0.000 kW
5.732 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.262 1.172 1.254 5.813
09 - 202217****** IQ7+ [5] VCOP 0.000 0.262 1.242 1.120 5.977
10 - 202244****** IQ7+M [5] VCOP 0.000 0.258 1.209 1.321 6.077
11 - 202224****** IQ7+M [5] VCOP 0.000 0.259 1.106 1.222 5.624
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.071 0.318 0.309 1.813 0.000 kW
0.372 kWh
0.000 kW
1.490 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.084 0.390 0.378 2.149
14 - 202216****** IQ7+ [5] VCOP 0.000 0.086 0.397 0.388 2.157
15 - 202245****** IQ7+M [5] VCOP 0.000 0.084 0.385 0.375 2.084
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.32 V Current/Power -1.32 A (-70 W)
Remain Capacity/Energy 451.4 Ah (23.1 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 75.2 % State Of Health 100.0 %
Run Time 14d 5h 55m to empty Report Date 2022-12-26 23:53
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.