Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.519 kW
01/13/2026 13:16 (2057 days) Production Consumption NET Usage
Now 2.762 kW 0.243 kW -2.519 kW
Today 9.601 kWh (0.723 kW) 6.823 kWh (0.514 kW) -2.778 kWh (-0.209 kW)
  - This Week 33.640 kWh (13.176 kWh/day) 39.386 kWh (15.427 kWh/day) 5.746 kWh (2.251 kWh/day)
  - This Month 109.451 kWh (8.719 kWh/day) 238.120 kWh (18.968 kWh/day) 128.669 kWh (10.250 kWh/day)
  - This Year 0.109 MWh (8.719 kWh/day) 0.238 MWh (18.968 kWh/day) 0.129 MWh (10.250 kWh/day)
Yesterday 14.545 kWh (0.606 kW) 16.751 kWh (0.698 kW) 2.206 kWh (0.092 kW)
Last 7 Days 58.918 kWh (8.417 kWh/day) 155.903 kWh (22.272 kWh/day) 96.985 kWh (13.855 kWh/day)
Last 30 Days 224.926 kWh (7.497 kWh/day) 612.416 kWh (20.413 kWh/day) 387.490 kWh (12.916 kWh/day)
Last One Year 6.097 MWh (16.705 kWh/day) 7.473 MWh (20.475 kWh/day) 1.376 MWh (3.770 kWh/day)
Lifetime Since PTO 35.675 MWh (17.338 kW/day) 39.750 MWh (19.318 kW/day) 4.074 MWh (1.980 kW/day)
Lifetime Since Install 35.709 MWh 40.330 MWh 4.620 MWh
Voltage/Current 252.6 V / 10.9 A 252.7 V / 1.0 A 252.6 V / -10.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/20/2023 22:46 (13.2 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 30.010 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.298 2.019 1.975 9.968 0.000 kW
1.969 kWh
0.000 kW
11.812 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.924 1.909 9.513
03 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.996 1.954 9.864
04 - 202232****** IQ7+ [5] VCOP 0.000 0.293 2.021 1.956 9.954
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.894 1.896 9.282
06 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.958 1.931 9.553
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.298 2.035 2.043 9.945 0.000 kW
2.023 kWh
0.000 kW
10.116 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.298 1.998 1.970 9.807
09 - 202217****** IQ7+ [5] VCOP 0.000 0.299 1.989 1.964 9.766
10 - 202244****** IQ7+M [5] VCOP 0.000 0.295 2.025 2.026 10.017
11 - 202224****** IQ7+M [5] VCOP 0.000 0.300 2.070 2.065 10.203
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.279 1.574 1.449 7.820 0.000 kW
1.624 kWh
0.000 kW
6.497 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.287 1.591 1.462 7.961
14 - 202216****** IQ7+ [5] VCOP 0.000 0.290 1.667 1.533 8.356
15 - 202245****** IQ7+M [5] VCOP 0.000 0.289 1.665 1.525 8.344
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.792 kWh
0.000 kW
1.584 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.234 1.584 1.583 11.031
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.